TABLE 7 <br /> OPERATIONAL UPTIME AND FLOW RATE <br /> FOR SOIL VAPOR EXTRACTION SYSTEM <br /> . Former ARCO Station No 6100 <br /> 25775 South Patterson Pass Road <br /> Tracy,California <br /> Hr Meter System Inf App Vac Days Between Sampling Cumulative Days Percent <br /> Date Flow Rate Dates <br /> Reading acfm "WC Total Das Uptime Total Das Uptime Utime <br /> Between March 9,2004 and November 2004,two 200 cfm King,Buck,&Associates SVE system were operated at the <br /> site Operational data for these SVE systems are included in Appendix D System operated under PTO No N-5026-1- <br /> &N-5026-2-0 <br /> A Solleco 500 cfm SVE system was installed at the site to replace King,Buck&Associates SVE <br /> 5/16/2005 systems The start-up of Solleco 500 cfm SVE system was conducted in accordance with ATC No N- <br /> 5026-2-3 <br /> 5/16/2005 5,4163 191 89 1904 System Start-up,collect samples and shutdown awaiting <br /> compliance verification <br /> 5/20/2005 5,4228 4452 231 2 System start-up for continuous operation after compliance <br /> verification <br /> 5/26/2005 5,5750 417 1 2448 1 639 634 639 634 99% <br /> 5/31/2005 5,6588 NM NM 465 349 1104 983 75% <br /> 6/1/2005 5,6591 Sy stem re-started after re-filling with propane <br /> 6/1/2005 5,660 1 324 231 2 105 005 1208 989 5% <br /> 6/7/2005 5,8040 335 23t 2 601 6 00 1809 1588 100% <br /> 6/14/2005 2 5,8794 2772 231 2 690 3 14 2499 1903 46% <br /> 6/17/2005 5,952 2 235 2 231 2 325 303 2823 2206 93% <br /> 7/6/2005 6,4049 338 680 1884 1886 4707 4092 100% <br /> 7/20/2005 6,741 6 269 680 1406 1403 61 13 5495 100% <br /> 7/26/2005 6,8844 257 680 590 595 6703 6090 100% <br /> 8/2/2005 7,0536 23925 81 6 698 705 7401 6795 100% <br /> 8/16/2005 7,391 5 252 81 6 1420 14 08 8820 8203 99% <br /> 8/22/055 15 NM 255 408 -- -- -- --8/22/05800 7,5337 247 95 2 593 592 9413 8795 100% <br /> 8/26/2005 7,6308 242 1360 404 405 98 17 9200 100% <br /> 9/6/2005 7,8960 119 1224 11 05 11 05 10923 10305 100% <br /> 9/19/2005 8,208 5 19575 95 2 1278 13 02 122 01 1 t6 07 100% <br /> 9/19/2005 System shutdown due to otential bearing malfunction in the liquid ring blower <br /> 12/5/20053 8,209 2 19575 460 77 11 003 19912 11610 -- <br /> 12/7/20054 8,2138 2871 74 8 205 019 2 05 019 934% <br /> 12/8/2005 8,2369 NM 74 8 103 096 200 15 11706 9333% <br /> 12/13/2005 8,3559 2262 81 6 496 496 701 5 15 100% <br /> 12/21/2005 8,4921 NM 680 8 15 568 20830 12274 70% <br /> 1/4/2006 818255 3 316 88 4 1349 1389 2050 1904 100% <br /> 1/24/2006'6 9,304 8 NM NM 2000 19 97 22830 14271 100% <br /> Arco_6I00_Quarter1y_0&M_500cfm Page 1 of 2 5TRA17U5 <br />