Laserfiche WebLink
COMPUTATION SHEET <br /> PROJECT TITLE ARCO Service Station No 6100 PROJECT NO U 6100-16-9 <br /> DESCRIPTION Mass Emission rates SHEE-i 2 OF 4 <br /> PREP BY Kiran Nagarafu DATE 11/9/2004 CHK BY G Kowtha DATE <br /> DATA <br /> The following parameters listed below were recorded between October 6, 2004, and November 4, 2004 <br /> 10/6/2004 10/14/2004 11/4/04 <br /> Total system influent air flow velocity(fpm) 8,000 9,600 7,375 <br /> Inner diameter of system influent pipe(Inches) 2 323 2 323 2 323 <br /> Area of system Influent pipe(ft) 0 029 0 029 0 029 <br /> Total system Influent air flow rate' (after dilution) (scfm) 23555 28266 21715 <br /> Total effluent air flow rate(scfm) 23555 28266 21715 <br /> System influent temperature(°F) 120 145 105 <br /> Applied vacuum ("WC) 12 12 13 <br /> Influent concentration of GRO(mg/m) 4,700 NS 3,200 <br /> System Influent concentration of GRO(mg/m) 1,600 2,000 1,000 <br /> Influent concentration of benzene(mg/m) 110 NS 110 <br /> System Influent concentration of benzene(mg/m3) 41 44 34 <br /> Influent concentration of MTBE(mg/m) <0 50 NS <0 50 <br /> System Influent concentration of MTBE (mg/m) <0 50 <2 5 <0 50 <br /> Effluent concentration of GRO(mg/m) 57 <50 160 <br /> Effluent concentration of benzene(mg/m) <0 50 <0 50 430 <br /> Effluent concentration of MTBE(mg/m3) <0 50 <0 50 <0 50 <br /> ' Field data sheets record flow rate(inches of water column, units) into the SVE system using a differential pressure guage <br /> and phot tube These readings were converted to flow velocity(fpm, units) using Dwyer Chart The air flow velocity in a pipe is <br /> converted to air flow rate using the following formula <br /> Flow Rate(scfm) =Area of Pipe(ft2)'Velocity(fpm) <br /> CALCULATION <br /> Since the total system Influent air flow rate is measured on the positive side of the blower, the system influent flowrate Is <br /> corrected for temperature only using the formula listed below <br /> Temperature Corrected Influent flow rate = System Influent flow rate `{[460 R+68 deg F]/[deg F+460 R]) <br /> Temperature corrected system influent flow rate for October 6,2004 21444 acfm <br /> Temperature corrected system influent flow rate for October 14, 2004 24669 acfm <br /> Temperature corrected system influent flow rate for November 4, 2004 20293 acfm <br /> ARCO 6100 Calc Sheets for Oct Nov 2004 fur <br />