Laserfiche WebLink
• Analytical data from samples collected on November 4, 2004 Indicated Inadequate destruction efficiency <br /> The SVE unit 2 was re-started on November 11, 2004, to troubleshoot for low destruction efficiency and <br /> air samples were collected after operating the system for approximately one hour The analytical results <br /> of the air samples collected on November 11, 2004, Indicated compliance with SJVAPCD permit <br /> requirements The SVE unit 2 was not re-started due to the proposed replacement of both units 1 and 2 <br /> by a 500 cfm Solleco thermal oxidizer <br /> During the fourth quarter 2004, the influent GRO concentrations to SVE unit 2 fluctuated in the ranges of <br /> 1,000 to 2,200 milligrams per cubic meter(mg/m) The average soil vapor extraction flow rates (including <br /> the dilution air) for SVE unit 2 were observed to be at 227 73 cfm at an average applied vacuum of 11 80 <br /> inches of water column During the fourth quarter 2004, approximately 1,000 9 pounds of GRO were <br /> extracted and abated by the SVE unit 2 Influent GRO and cumulative GRO mass removed from both <br /> SVE units 1 and 2 are presented in Figures 6 and 7 Since the system start-up, a cumulative mass of <br /> 9,625 pounds of GRO has been removed from the subsurface beneath the site by both the units <br /> ATTACHMENTS- <br /> • Table 1 Product Monitoring and Removal Summary <br /> • Table 2 Groundwater Level Data <br /> • Table 3 Groundwater Analytical Summary <br /> • Table 4 Groundwater Analytical Results for Oxygenates and Additional Compounds <br /> • Table 5 Summary of Wells <br /> • Table 6 Flow Rates and Analytical Results of Air Sample Analyses-- Unit 1 (SL No 9321) <br /> • Table 7 Flow Rates and Analytical Results of Air Sample Analyses—Unit 2 (SL No 9230) <br /> • Table 8 Operational Uptime and Flow Rate For Soil Vapor and Extraction System <br /> Unit 1 (SL No 9321) <br /> • • Table 9 Operational Uptime and Flow Rate For Soil Vapor and Extraction System <br /> Unit 2 (SL No 9230) <br /> • Table 10 Extraction and Emission Rates— Unit 1 (SL No 9321) <br /> • Table 11 Extraction and Emission Rates—Unit 2 (SL No 9230) <br /> • Figure 1 Site Location Map <br /> • Figure 2 Site Plan <br /> • Figure 3 Groundwater Elevation Contour Map, Upper Water Bearing Zone (4th Quarter 2004) <br /> • Figure 4 Groundwater Elevation Contour Map, Lower Water Bearing Zone (4th Quarter 2004) <br /> • Figure 5 Groundwater Analytical Summary (Fourth Quarter 2004) <br /> • Figure 6 Influent GRO and Cumulative GRO Mass Removed Over Time—SVE Unit 1 <br /> • Figure 7 Influent GRO and Cumulative GRO Mass Removed Over Time—SVE Unit 2 <br /> • Appendix A Field Data Sheets <br /> • Appendix B Sampling and Analysis Procedures <br /> • Appendix C Certified Analytical Reports with Chain-of-Custody Documentation and EDF <br /> Verification <br /> • <br /> K\Bp-Arco for URS\6100\Quarterly\2004\Arco_6100_4Q04 doe STRA7U5 <br />