Laserfiche WebLink
Canepa's Car Wash - SVE System <br /> S stem Status Air Flow PID Status <br /> Destruction <br /> Temp Vacuum Barom Velonty Flo,4 Inlet VOCsm Stack VOCsaut Efrtctency Air Oil <br /> Fate Technician System Status (F) ("'H{) Pitot Units Temp(F) Q.FIe) (ft min)' (efm),• (Ppm) (}bslday) (ppm) (,,,,day) (%) Alarms Tape Filter Leel Condensate Comments <br /> 319199 RM B off E off Failed Inspection <br /> 3110199 RM B off E off <br /> 3/11199 RM B off E off <br /> 3115/99 MP B off E on 281 1 9 9932% ok ok ok ok ok <br /> 3116199 MP 8 on E on 170 14 9918% ok ok ok —6" Changed oil <br /> 3117199 MP B on JE on 6 000 fUmin r 60 6 000 295 255 4333 07 015 9973% ok ok ok —6" <br /> 3118199 MP a on JE on 5 750 ftfmin 61 5 750 282 288 4689. 28 059 9903% ok ok ok <br /> 3119199 MP 8 on JE on 5 250 fllmin 60 5,250 258 125 1858 21 041 9832% ok ok ok —10' Weathered gas odor <br /> 3122199 MP B on 1= on 5,400 funim 61 5,400 265 454 6942 24 048 9947% ok ok `ok 13" Fresh gas odor <br /> 3125199 MP B on E on 1449 35 5,500 ft/min 61 5,500 270 502 7819 09 018 9982% none ok ok ok 60%full New condensate drum added <br /> 3129/99 MP a on E on 1447 35 5 400 fflmin 61 5 400 265 365 55 81 05 010 9986% none ok ok ok —8' Greased blower <br /> 412199 MP a on E on 1440 35 5 400 fumin 62 5 400 265 none out ok ok 33%full.PID not available <br /> 416/99 MP B off E on 1445 35 5 500 ftlmin 58 5 500 270 none out ok ok 30 gal Flame failure unit started ok <br /> 4112199 MP 8 off E off HI temp alarm Would not start <br /> 4/14199 MP B off E off Blown fuse-bad time delay relay <br /> 4115199 BC a off E on 1430 3 5 1,050 0 6 99 94% none out ok ok 30 gal Replace fuse 2 and time delay relay <br /> Changed oil <br /> 4126/99 MP B off E on 1430 35 ok 30 gal <br /> 4128199 RM B off F off Shut down on 4126199 at—5 00 pm <br /> 4129199 MP a off E on 1450 35 P35gal <br /> Bypass timer relay <br /> 512199 BC 8 on E orf 85 35 high Shut off after failure <br /> 514199 BC B off E on 1450 35 1 6 rvh,o 61 5,023 282 809 131 57 36 076 9956% none ok ok okRe lace fuse 2 with 5 amp fuse <br /> 5110199 BC B on E cuff o Points in actuator are fused together <br /> 5113199 BC B off E on 1450 36 none ok Replace actuator <br /> 5/19199 BC B on E on 1450 34 1 62 in1H2O 67 29961 5 084 285 330 5431 1 6 034 9952% ok ok ok ok <br /> 5/27199 RM B off E 1420 32 1 9 in11-12O 70 5 521 310 320 5716 06 014 99 81%a ok ok ok ok 35 gal Off-reset 3 times before starting <br /> 619199 BC IR on E on 1450 28 1 6 IrVH20 77 2995 5 101 254 398 5835 52 1 01 9869% ok ok ok ok 35 gal rel humidity 36% calibrated 10 scare <br /> 6122199 BC JB off E on 1450 35 1 8 in/H20 85 297 5,473 271 1015 16869 48 980 9527% ok ok ok ok 38 gal reset restart 24%rel humidity <br /> 711!99 BC B on E on 1450 35 1 8 in1H,o 83 2995 5,440 266 890 13650 25 503 9719% ok new ok ok 39 gal Changed oil <br /> 716199 BC B off E on 1450 3.5 1 8 trvH,o 79 2989 5,426 261 763 11500 94 1 87 9877% ok ok ok ok 39 gal took measurements RH 30% <br /> 7/12199 BC B on E on 1450 35 1 8 inIH20 861 298, 5,469 264 862 131 44 126 252 9854% ok ok ok ok 39 gal reconfigured vents rel, humidity 30% <br /> 7123/99 BC B on E on 1450 2 B 1 7 inm2o 79 30 11 5 254 256 1 411 6067 19 371 9538% ok ok ok ok 39 gal 55%relative humidity <br /> 7130199 BC B on E on 1450 68 2 2 inlH2O 72 29941 5 954 286 1 1280 211 12 42 894 9672% ok new ok ok 39 gal 22%relative humidity <br /> 8118199 RDM B on E on 1450 Go 1064 68 9936% ok ok 40 gal new vacuum working well <br /> 8130199 BC B on E on 1450 55 2 6 in/H,o 80 2998 6,517 321 250 4627 1 0 023 9960% ok ok ok ok 38 gal calibrated PID,rel hurnidity 43% <br /> 917199 BC B an %onl <br /> 2 B 1 7 tn1H2O 79 2978 5,282 301 1210 21042 13 288 9893% ok ok ok ok 38 gal relative humidity 69% <br /> 9/20199 BC tf on 28 1 8 inIH2O 74 2995 5,395 262 146 22 08 22 044 9849% ok ok ok ok 38 gal relative humidity 55% <br /> 1011/99 BC B on 25 1 8 inrH2O 75 3004 5 392 263 158 2393 22 044 98 61% ok ok ok ok 39 gal RH=73% oil change,calibrated PID <br /> 10118199 BC B on 25 1 0 irVH2072 3011, 4,003 197 631 718 07 011 9889% ok ok ok ak 39 gal RH=53% clean UV detector <br /> 11/16/99 BC B on 35 1 0 in/H,o 68 2997 3997 19fi 183 2074 22 035 9880% ok ok ok ok 39 gal relative humidity 68% change oil <br /> 12113199 BC Bon 35 1 0 in1H2063 29871 39851 197 1 177 2011 28 045 9842% ok ok ok ok 139 gal relative humidity 93% <br /> SVG Rofl formsJHKd$heeti 1119101 <br />