Laserfiche WebLink
' Quarterly Monitoring Report October 2000 <br /> Canepa's Car Wash(Pacific Avenue) <br /> Page-a <br />' TABLE 1 <br /> GROUNDWATER ELEVATION DATA (OCTOBER 12,2000) <br /> MW-1 THROUGH MW-8 <br />' Well1 <br /> We 1 Casing Well Collar Depth to Groundwater <br />' ID Screen Elevation Water Elevation <br /> Interval (feet) (feet) (feet) <br /> (feet—bgs) <br />' MW-1 50 -70 13 45 35 05 -21 60 <br /> MW-2 50-70 1327 3468 -2141 <br />' MW-3 50-70 13 50 35 35 -2185 <br /> MW-4 50 -70 13 82 35 16 -21 34 <br />' MW-5 50 -70 1269 3467 -2198 <br /> MW-6 45 -65 1162 3409 -2247 <br /> MW-7 45 -65 13 18 35 16 -2198 <br /> MW-8 45 -65 1326 35 10 -21 84 <br /> 4 2 LABORATORY ANALYSES <br /> The groundwater samples were analyzed by GeoAnalytical Laboratories, Inc for total petroleum <br /> hydrocarbons quantified as gasoline (TPH-G) by Method 5030/LUFT The groundwater samples were <br /> I also analyzed for methyl tertiary-butyl ether (MTBE) and for benzene, toluene, ethyl benzene, and total <br /> xylenes (BTEX) by EPA Method 8021B <br /> A summary of the laboratory analytical results is presented in Table 2 (below) Laboratory report sheets <br /> indicating analytical methods used, detection limits, and the results of the analyses are included in <br /> Appendix C Historical groundwater analyses are presented in Table A, Appendix B <br /> I <br /> I <br /> CONDOR <br />