Laserfiche WebLink
Canepa's Car Wash - SVE System <br /> System Status Air Flow PIU Slams <br /> Deswcnon <br /> Temp Vacuum Sarom �elocty Flow Inlet kocsm Stack VOCs out EtYctency Atr Oil <br /> Dale Technician Svsten Slaws (F) (m lf¢) Pitot Un,K Temp(F} tm Hg) (FI min}• (cfm)" fppml (Ib�fdaY) (ppm! (Poe/day) (ro) Alarm] Tape Fiber Level Cvndenvate Comments <br /> 319199 1 RM B off E off Faded Inspection <br /> 3110/991 RM B off E off <br /> 3111199 RM B off E off <br /> 3115!99 MP B off E on 281 1 9 9932% ok ok ok ok ok <br /> 3116199 MP B on E on 170 1 4 99 18% ok ok ok --6" Changed of <br /> 3117199 MP 8 on E cn 6,000 Rimm 60 6,000 295 255 4333 07 0 15 9973% ok ok ok —6" <br /> 3118199 MP B on JE on 5 750 fumm 61 5750. 282 288 4689 2 8 059 9903% ok ok ok —8" <br /> 3119!99 MP e on JE on 5 250 filmin 60 5,250 258 125 1858 21 041 9832% ok ok ok --10' Weathered gas odor <br /> 3122199 MP B on E cn 5,400 fVmin 61 5,400 265 454 6942 24 048 9947% ok ok ok 13' Fresh gas odor <br /> 3125199 MP B on E on 1449 35 5 500 ft/min 61 5 500 270 502 78 19 09 0 18 99 82% none ok ok ok 60%full New condensate drum added <br /> 3129199 MP B on E on 1447 35 5,400 ft/min 61 5 400 265 365 5581 05 010 99 86% none ok ok ok —8" Greased blower <br /> 412199 MP B on E on 1440 35 5 400 ftfmin 62 5 400 265 none out ok ok 33%full PID not available <br /> 416199 MP B orf E on 1445 35 5 500 fumm 58 5 500 270 none out ok ok 30 gal Flame failure Unit started ok <br /> 4112199 MP B off E cff Ht temp alarm Would not start <br /> 41141991 MP B off E 0 Blown fuse-bad time dela rela <br /> 4115199 BC B off E an 1430 35 1,050 06 9994% none out ok ok 30 gal Replace fuse 2 and time delay relay <br /> Changed oil <br /> 4126199 MP B off E on 1 1430 35 1 ok 30 gal <br /> 4128199 RM B off E off Shut down on 4126199 at—5 00 pm <br /> 4129199 MP B off E cn 1450 35 1 30 gal Bypass timer relay <br /> 512199 BC B on E off 85 35 high Shut off after failure <br /> 514199 BC B off E on 1450 3 5 16 inrH2O 61 5,023 282 809 131 57 36 0 76 9956% none ok ok ok 30 gal Replace fuse 2 with 5 amp fuse <br /> 5/10199 BC 8 on E off B 1 1 Pomts In actuator are fused together <br /> 5113199 13C B off E on 1450 35 1 none ok 35 gal Replace actuator <br /> 5119199 BC B on E cn 1450 34 162 infH2O 67 2996 5,084 285 330 5431 16 034 9952% ok ok ok ok 35 gal <br /> 5127199 1 RM 8 orf IE 1420 32 1 9 in/H,o 70 5,521 310 320 57 16 06 014 9981% 1 ok ok ok ok 35 gal Gff-reset 3 times before starting <br /> B E <br /> B E <br /> B E <br /> B E <br /> SVG Rofl fofmsJHKd xlsSheetl 6128199 <br />