Laserfiche WebLink
Installation of a new SVE system has been approved for this site During the Fall of 1997, an Authority to <br /> Construct permit was applied for front the San Joaquin Valley Unified Air Pollution Control District for the <br /> installation of a SVE system Prior to granting unconditional approval of the installation of the SVE <br /> system, the Underground Storage Tank Clean-Up Fund has indicated the need for additional investigation <br />' Condor has conducted the installation and sampling of two soil borings adjacent to the SVE well array The <br /> investigation included soil vapor screening using the Simulprobe sampling device in soil vapor collection <br /> triode Results indicated high levels of volatile organic compounds are present in the soil vapor at the site <br /> The findings of the investigation were reported in Report—Soil and Groundwater Investigation and dated <br /> June 12, 1998 <br /> i <br /> 1 <br /> 1 <br /> 1� <br /> 1 <br /> 1 <br /> 1 <br /> 1 <br /> 1 <br /> 3 <br />