11 Table 1 <br /> Groundwater Monitoring Data and Analytical Results <br /> Fortner Unocal Service Station#2859 <br /> 1665 Pacific Avenue <br /> Stockton,California <br /> EXPLANATIONS <br /> Groundwater monitoring data and laboratory analytical results prior to Ma{h 6, 1998,1were compiled from reports prepared by MADS Services,Inc <br /> TQC=Top of Casing ji B E=Benzene (ppb)=Parts per billion <br /> (ft)=Feet 1� TIL Toluene ND=Not Detected <br /> DTW=Depth to Water j E��Ethylbenzene (D)=Duplicate <br /> GWE=Groundwater Elevation j X;=Xylenes --=Not Measured/Not Analyzed <br /> (ms])=Mean sea level MTBE=Methyl tertiary butyl ether QA=Quality Assurance/Trip Blank <br /> TPH-G=Total Petroleum Hydrocarbons as Gasoline EB=Equipment Blank <br /> * TOC elevations have been surveyed relative to mean sea level On February 10, 1999,TOC measurements were re-surveyed relative to City of Stockton BM#24, <br /> located in monument box at the northwest corner of Pacific Avenue and Har ing Way,(Benchmark Elevation=9 71 feet,NGVD29) <br /> On June 31,2001,the following wells were surveyed MW-4,MW-6 and MW-1 I through MW-14 using the previous benchmark. - <br /> r` <br /> Laboratory report indicates the hydrocarbons detected appeared to be{a gasoline and non-gasoline mixture <br /> z Laboratory report indicates the hydrocarbons detected did not appear'to be gasoline <br /> 3 <br /> Detection limit raised Refer to analytical reports <br /> MTBE by EPA Method 8260 <br /> 5 Laboratory report indicates unidentified hydrocarbons C6-C12 <br /> 6 Laboratory report indicates gasoline and unidentified hydrocarbons x8 <br /> r Well development only - <br /> a Laboratoryreport indicates gasoline and unidentified hydrocarbons C6-C121 <br /> 9 Laboratory report indicates discrete peaks - <br /> 10 Laboratory report indicates gasoline C6-C12 <br /> " Laboratory report indicates weathered gasoline C6-C12 1 j <br /> iz Laboratory report indicates hydrocarbon pattern is present in the requested fuel quantitation range,but does not resemble the pattern of the requested fuel <br /> 13 11 <br /> Laboratory report indicates the result was reported with a high bias due to the continuing calibration verificcation falling outside acceptance criteria <br /> 14 !� <br /> Laboratory report indicates gasoline C6-C 10 <br /> 'S Laboratory report indicates discrete peak @ C7 I <br /> E6Current laboratory analytical results to not coincide with historical data,and although the laboratory results were confirmed,it appears that the samples were switched <br /> ANALYTICAL METHODS <br /> EPA Method 8015 for TPH-G <br /> EPA Method 8020 for BTEX and MTBE(except where noted) <br /> EPA Method 8260 for MTBE(except where noted) <br /> A0/19/43 <br /> 2859 x1054 11 . <br />