Laserfiche WebLink
Adek <br /> WELL MW-11 CONSTRUCTION DETAIL <br /> M E C <br /> + A Total Depth Of Boring 60 ft <br /> H B Diameter Of Boring $ in <br /> • y Drilling Method <br /> Hollow—stem Auger <br /> C Top Of Box Elevation ft <br /> ❑ Referenced To Mean Sea Level <br /> ❑ Referenced To Project Datum <br /> F I D Casing Length 60 ft <br /> Material Schedule 40 PVC <br /> E Casing Diameter 2 in <br /> F Depth To Top Perforations 50 ft <br /> G Perforated Length 10 ft <br /> aJ1 Perforated Interval From 50 to 60 ft <br /> D Perforation Type Machine slotted <br /> A Perforation Size 002 in <br /> H Surface Seal From 0 to 1 5 ft <br /> Seal Material Concrete <br /> Backfill From 1 5 to 46 ft <br /> Backfill Material Neat Cement <br /> J Seal From 46 to 48 ft <br /> G — K Seal Material Bentonite <br /> K Gravel Pack From 48 to 60 ft <br /> Pack Material Lonestor #3 <br /> L Bottom Seal None ft <br /> Seal Material <br /> M Vault Box, Locking Well Cap, Lock <br /> L <br /> B <br /> Note Depths Measured From Initial Ground Surface <br /> Gettler - Ryan Inc. PROPOSED WELL CONSTRUCTION DETAIL FIGURE <br /> Former Unocal Service Station No 2859 <br /> 3164 Cold Camp Drive, Suite 240 1665 Pacific Avenue 3 <br /> Rancho Cordova, CA 95670 Stockton, California <br /> JOB NUMBER REVIEWED BY DATE REVISION DATE <br /> 240072 06/99 <br />