My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0005708
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
2402
>
3500 - Local Oversight Program
>
PR0545640
>
ARCHIVED REPORTS_XR0005708
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2020 2:23:57 PM
Creation date
5/5/2020 1:44:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0005708
RECORD_ID
PR0545640
PE
3528
FACILITY_ID
FA0003900
FACILITY_NAME
PACIFIC PRIDE COMMERCIAL FUEL
STREET_NUMBER
2402
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95204
APN
12506001
CURRENT_STATUS
02
SITE_LOCATION
2402 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' 26 April 2002 <br /> AGE-NC Project No 95-0173 <br /> Page 2 of 8 <br /> for stabilization at regular purge-volume intervals using either an Oakton or a Hydac water analyzer <br />' Field data and logs are Included in Appendix A Purged groundwater was containerized In 55-gallon <br /> drums and was stored on-site in an area lacking general public access <br /> 2 2 GROUND WATER SAMPLING <br /> tFollowing well purging,ground water levels in the wells achieved a minimum of 80 percent recharge <br /> prior to sample collection except for wells MW-11 and MW-13 which had been purged "dry" <br />' Ground water samples were collected from the purged wells utilizing new,disposable polyethylene <br /> bailers and transferred into 40-m1 EPA-approved VOA vials containing 0 5 ml 18% hydrochloric <br /> acid as a sample preservative Care was taken to ensure that visible air bubbles were not present in <br />' the vials after filling and capping Ground water sample containers were labeled with the well <br /> designation, date, time, and sampler's initials <br /> 2 3 LABORATORY ANALYSIS OF GROUND WATER SAMPLES <br /> lie After labeling,each ground water sample was logged on a chain-of-custody form,placed in a chilled <br /> container and transported to a California Department of Health Services (DHS)-certified laboratory <br /> to be analyzed for <br />' Total petroleum hydrocarbons quantified as gasoline (TPH-g) by EPA Methods <br /> 1 Y <br /> P5030/8015M, <br /> • Benzene,toluene,ethylbenzene and xylene(BTEX)and methyl tertiary-butyl ether(MTBE) <br /> by EPA Method 8020, and <br /> • The fuel additives tertiary butanol (TBA), di-isopropyl ether (RIPE), ethyl tert butyl ether <br /> (ETBE), tert amyl methyl ether (TAME) and MTBE by EPA Method 8260 Modified, 1,2- <br /> dichloroethane (1,2-DCA) and ethylene dibromide (EDB)by EPA Method 8260 <br /> z n CnT7 v e vni2 FXTR A C T1QN/1N_STTT T ATR SPARGE SYSTEM <br /> J•v• i..svaJu • •a+ v��a. <br /> Between 01 October and 31 December 2001 (fourth quarter 2001), SVE remediation was in <br /> continual operation at the site, utilizing a Solleco Ecat 250 catalytic converter vapor extraction <br /> system to apply an induced vacuum to wells VW-1 through VW-7,during this time,IAS remediation <br /> also continued, with air sparging through wells MW-1 through MW-3 and AW-1 through AW-7 <br /> tSVE and IAS procedures for the site were described in the AGE-prepared Remedial Action Work <br /> • Plan dated 30 December 1998, and approved by the SJCEHD by letter dated 20 April 1999 <br /> Advanced CeoEnvironmental,Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.