' CASTLE ANALYTICAL LABORATORY <br /> Environmental Testing Services 2333 Shuttle Drive,Atwater,CA 95301 Phone (209)384-2930 <br /> ' Certificate#2480 Fax (209)384-1507 <br /> F <br /> vanced GeoEnvironmental, Inc Client Project ID Cal Fuels Sampled 06-20-02 <br /> Northern California Reference Number 4805 Received 06-21-02 <br /> 837 Shaw Road Sample Description Water Extracted 06-25-02 <br /> Stockton, CA 95215 Sample Prep/Analysis Method EPA 503018015, 8020 Analyzed 06-25-02 <br /> Attn Tim Cuellar Lab Numbers 4805-1W,2W,3W,4W, 5W Reported 07-08-02 <br /> t <br /> TOTAL PETROLEUM HYDROCARBONS -GASOLINE <br /> ' WITH BTEX DISTINCTION <br /> ' ANALYTE REPORTING LIMIT SAMPLE ID SAMPLE ID SAMPLE ID SAMPLE ID SAMPLE ID <br /> MW 1 MW 2 MW 3 MW 4 MW 5 <br /> 062002 062002 062002 062002 062002 <br /> ' (ug/L) (ug/L) (ug/L) (ug/L) (ug/L) (ug/L) <br /> MTBE 0 50 NO NO NO ND 081 <br /> BENZENE 050 NO 21 5100 2700 ND <br /> ' TOLUENE 050 NO NO 720 60 NO <br /> ETHYL BENZENE 050 NO 26 2100 1800 ND <br /> ' TOTAL XYLENES 050 23 16 7100 2800 NO <br /> GASOLINE RANGE <br /> tHYDROCARBONS 50 520 2300 51000 35000 ND <br /> Report Limit Multiplication Factor 1 5 200 100 1 <br /> 1 <br /> 1 <br /> Surrogate%Recovery FID 115%1 PID 979% FID 171%I PID 129% FID 109%/PID 102% FID 132%IPID 115% RD 10i%1PID t03% <br /> Instrument ID VAR-GC1 VAR-GC1 VAR-GC1 VAR-GC1 VAR-GC1 <br /> i <br /> Analytes reported as NO were not detected or below the Practical Quantitation Limit <br /> Practical Quantitation Limit=Deporting Limit x Report Limit Multiplication Factor <br /> 1 W <br /> ' ANALYST APPROVED BY <br /> clan-i Cone J Phillips <br /> abaretory Duector <br />