11RONMENTAL HEALTH DEPARTMENT <br /> 600 E&_. Main Street, Stockton, California 95202-31,-,, <br /> Telephone: (209) 468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd/unitiii.html <br /> CONTINUATION FORM Page: 5 of 5 <br /> OFFICIAL INSPECTION REPORT Date: 05-26-10 <br /> Facility Address: Arco AMPM 1711 East Yosemite Ave, Manteca Program: UST <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Submit to SJC EHD within 30 days (06-26-10): <br /> 1. one copy of the completed Return to Compliance Certification <br /> 2. a corrective action statement for the above violations <br /> 3. monitoring system certification, line leak detector and spill containment test results from testing <br /> on 05-26-10 <br /> Notes- <br /> 1. <br /> otes:1. All liquid detection sensors (located in UDCs, STP sumps and fill sumps, annulars), sensor out <br /> are provided with audible and visual from the overfill prevention alarm system <br /> 2. Certification of Financial Responsibility and Letter from Chief Financial Officer due by 10-2010. <br /> Submit a copy of CFR and Letter from CFO tovia postal, f or email by 10-2010. <br /> Nw. <br /> 3. Secondary containment testing last performedNext due by2011. Submit a 48 hour <br /> test notification of the secondary containment testing and submit its test results within 30 days of <br /> testing to SJC EHD. <br /> 4. Technician found the 89 product line leak detector (LLD) minor leaking from the turbine due to <br /> insufficient amount of thread sealant/doping material. 89 LLD was not able to be tested until the <br /> leak from the LLD on the turbine was stopped. When technician removed the VMI 99-LD2000, <br /> the LLD came out of the turbine easily with a single untwist motion. The LLD was not properly <br /> installed into the turbine snuggly. Technician added more thread sealant/doping material to the <br /> line leak detector and properly placed into the turbine. <br /> 5. Technician found it difficult to remove both 89 and 91 cast iron test plugs in the test port of the <br /> shear valve on Dispenser 13/14. Both test plugs had too much torque placed on. Both test <br /> plugs' threads had been stripped. Technician replaced both test ports with new test plugs. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($115). <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: Received By: Title: <br />