My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2010 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2023 10:33:18 AM
Creation date
5/5/2020 3:36:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2012
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AW <br /> Appendix VI <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23,California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A General information <br /> Facility <br /> Name: MANTECA ARCO Bldg.No.: <br /> Site 1711 E. YOSEMITE AVE. city: MANTECA, CA _ Zip: 95336 <br /> Facility Contact Person: DEEPA Contact Phone No.: ( ) <br /> Make/Model of Monitoring System: V EEDER ROOT TLS-350 Date of Testing/Servicing: 9/28/2011 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the approgriate boxes to Indicatespecific equipment Inspected/serviced: <br /> Tank ID 87 Tank Size: 15 K Tank ID: 89 Tank Size: 15 K <br /> ® In-Tank Gauging Probe. Model: MAG 1 ® In-Tank Gauging Probe. Model: MAG 1 <br /> 0 Annular Space or Vault Sensor. Model: 409 ® Annular Space or Vault Sensor, Model: 409 <br /> ® Piping Sump/Trench Sensor(s). Model: 323 ® Piping Sump/Trench Sensor(s). Model: 323 <br /> ® Fill Sump Sensor(s). Model: 323 ® Fill Sump Sensor(s), Model: 208 <br /> ® Mechanical Line Leak Detector. Model: STP-MLD ® Mechanical Line Leak Detector. Model: 99 LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-level Sensor Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2) ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank Size: Tank ID: 91 Tank Size: 12 K <br /> ® In-Tank Gauging Probe. Model: ® in-Tank Gauging Probe. Model: MAG 1 <br /> ® Annular Space or Vault Sensor. Model: ® Annular Space or Vault Sensor. Model: 409 <br /> ® Piping Sump/Trench Sensor(s). Model: ® Piping Sump/Trench Sensor(s). Model: 323 <br /> ❑ Fill Sump Sensor(s). Model: ® Fill Sump Sensor(s). Model: 323 <br /> ❑ Mechanical Line Leak Detector. Model: ® Mechanical Line Leak Detector. Model: X L D <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2) ❑ Other(specify equipment type and model in Section E on Page 2) <br /> Dispenser ID: 1/2 Dispenser ID: 3/4 <br /> ® Dispenser Containment Sensor(s), Model: 323 ® Dispenser Containment Sensor(s). Model: 323 <br /> ® Shear Valve(s). ® Shear Valvele). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chdin(s). <br /> Dispenser ID. 5/6 Dispenser ID: 7/8 <br /> ® Dispenser Containment Sensor(s). Model: 323 ® Dispenser Containment Sensor(s). Model: 323 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s), ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9/10 & 11/12 Dispenser ID: 13/14 & 15/16 <br /> ® Dispenser Containment Sensor(s). Model: 323 & 323 ® Dispenser Containment Sensor(s). Model: 323 & 323 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment Identified in this document was Inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is Information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): ZANE NIMMO Signature: <br /> Certification No. A28446 License No: 04-1676 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> 'resting Company Address: 416 2 STREET GALT,CA 95632 Dale of Testing/Servicing: 3/28/11 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.