My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2010 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2023 10:33:18 AM
Creation date
5/5/2020 3:36:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2012
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.segov.org/ehd/unitiii.html <br /> CONTINUATION FORM Page: 3 of 4 <br /> OFFICIAL INSPECTION REPORT Date: 03/28/11 <br /> Facility Address: 1711 Yosemite Avenue, Manteca Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> UST Inspection Report <br /> 3. UST facility and tank forms for the 87, 89, 91 tank on file with the EHD are not current. Any change of <br /> information on these forms must be submitted to the EHD within 30 days of the changes. Immediately <br /> complete and submit a copy of the facility and tank forms to the EHD within 30 days of receiving this <br /> report. Complete a separate tank form for each tank. <br /> 4. Current financial responsibility documents have not been submitted to the EHD. Current financial <br /> responsibility documents are required to be submitted annually. Complete and submit a copy of the <br /> financial responsibility within 30 days of receiving this report. <br /> 5. The monitoring and response plans on site are not current and not approved by the EHD. The <br /> monitoring and response plans must be current and approved by the EHD. Complete and submit a copy <br /> of the monitoring and response plans for approval by the EHD within 30 days of receiving this report. An <br /> approved copy will be returned for your records. <br /> 7. Alarm logs for 1-3, 1-5, 1-7, L15 - 3/16/11, L12 - 3/28/11, L13 - 3/6/11 were not found on site and also <br /> how each violation were corrected. These records shall be kept on site for at least 3 years. Immediately <br /> locate and maintain the alarm log on site and submit how the violation was corrected. <br /> 17. The 91 turbine I ne leak detector failed to detect a leak when tested. All line leak detectors shall be <br /> capable of detecting a 3-gallon per hour leak at 10 psi. Immediately have a properly licensed, trained, <br /> and certified contractor repair or replace the failed leak detector (LG 113-x listed, if applicable) and <br /> obtain a permit withi-i one business day from the EHD. If the failed leak detector can't be replaced <br /> immediately, there is a possibility that the 91 grade UST system may be red tagged to prevent fuel <br /> inputs. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($122). <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: Received By: Title: <br /> v/1. -CA! <br /> EHD 23-02-003 Rev 08/10/10 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.