Laserfiche WebLink
Third Quarter 2001 Monitonng and Sampling Report 2 <br /> 7-Eleven Inc Store No 17334 4501 North Pershing Avenue,Stockton CA October 1 2001 <br /> ' Groundwater Monitoring Data <br /> ' Before monitoring,the well caps were opened to allow the water in each well to stabilize to atmospheric <br /> pressure The DTW was measured to the nearest 0 01 foot from the top of the well casing using an <br /> interface probe, and the resulting data was used to prepare a potentiometric surface map (Figure 2) <br /> Based on the potent4ometnc surface map, groundwater flow is toward the north at an approximate gradient <br /> of about 0 02 foot per foot Groundwater monitoring results for the quarter and historical monitoring results <br /> are presented in Tables 1 and 2, respectively(Attachment 2) Field data sheets are included in Attachment <br /> ' 3 <br /> Monitoring Well Sampling and Analytical Results <br /> ' Quarterlygroundwater well- <br /> casing g r samples were collected after purging at least 4 well casing volumes of groundwater <br /> ' from each monitoring well, unless the well was purged dry The groundwater samples were collected using <br /> disposable bailers Groundwater samples were placed in analysis-specific containers with analysis-specific <br /> preservative The samples were then sealed using Teflon septum caps, labeled with the fob identification <br /> number,the sample number, date,time, and type of laboratory analysis required The samples were <br /> stored on ice and transported with a chain-of-custody record to a state-certified laboratory for analysis <br /> Groundwater samples were analyzed for BTEX and TPH-G using Environmental Protection Agency(EPA) <br /> methods 8021 B/modified 8015, and for oxygenates MTBE,TBA, DIPS, ETBE, and TAME using EPA <br /> method 82608 <br />' Analytical results for the quarterly sampling event are presented in Table 1, and historical laboratory <br /> analytical results are summarized in Table 2 Highest dissolved benzene concentrations were reported in <br /> well MW-5A at 3,200 micrograms per liter(ug/L) Dissolved MTBE concentrations were highest in wells <br />' MW-4 (4,800 ug/L) and MW-5A(1,300 ug/L) Other monitoring wells contained less than 5 ug/L MTBE, <br /> except well MW-5B which contained 15 ug/L Selected dissolved constituents are plotted on Figure 2 The <br /> laboratory analytical reports are included in Attachment 4 <br />' Field records indicate thea resence of o <br /> p possible offsite contaminant source, a remediation system is present <br />' on the property located directly across North Pershing Avenue from the 7-Eleven site This finding may <br /> indicate plume mixing in the area of well MW-4 with another hydrocarbon source (not 7-Eleven) Other <br /> quarterly data obtained during this sampling event are consistent with previous findings, indicating the onsite <br />' hydrocarbon source is in the vicinity of the underground storage tanks Dissolved plume constituent <br /> concentrations in the deeper nested well MW-5B indicate vertical plume delineation near the source area <br />' Pnor to purging, dissolved oxygen (DO) levels were recorded in each well Dissolved oxygen levels indicate <br /> generally anearobic conditions (less than 2 milligrams per liter (mg/L)) (Table 1) As mentioned in previous <br /> quarterly reports, a well search database for public water supply wells located within one mile of the site <br />' indicates that there are no public water supply wells located within 4,000 feet downgradient from the site <br /> 17334013 QMR DOC <br /> 1 <br />