Laserfiche WebLink
by EA and by the PHS/EHD, that the groundwater elevation differences are due in part to <br /> seasonal agricultural groundwater pumping, and seasonal natural groundwater recharge. <br /> 4.3 Soil Analytical Results <br /> Soil samples were collected and submitted for laboratory analyses as described previously <br />' The soil analytical results are presented in Table 2. Soil analytical data sheets and chain-of- <br /> custody records are included in Appendix III. <br /> The analytical results of the soil sampling indicates that concentrations of TPH as gasoline <br /> (TPH-G) were detected in the soil collected from monitor wells MW2 through MW5. <br />' BTEX compounds were detected in the soil samples collected from monitor wells MW2, <br /> MW3 and MW4 The maximum concentrations of petroleum hydrocarbons detected in soil <br /> samples were from the samples collected at 25 feet below ground surface, at the historical <br />' highest seasonal groundwater elevation. <br /> No concentrations of TPH-G were detected in the soil samples collected from boring MW1. <br />' TPH-G were detected in the soil sample collected from boring MW2 at a depth of 25 feet <br /> below grade at a concentration of 22 mg/kg, at a concentration of 420 mg/kg in the soil <br /> sample collected from boring MW3 at 25 feet, and in the soil sample collected at 30 feet <br />' below grade immediately above first encountered groundwater at a concentration of 27 <br /> mg/kg. TPH-G was detected in the soil sample collected from boring MW4 at 25 feet <br /> below grade at a concentration of 160 mg/kg, and in the soil sample collected at 30 feet <br /> below grade immediately above first encountered groundwater at a concentration of 160 <br /> mg/kg. In the soil sample collected from MW5 at a depth of 25 feet below grade the <br /> TPH-G concentration was 12 mg/kg <br /> ' Analytical data indicated that no concentrations of BTEX were detected in the soil samples <br /> collected and analyzed from borings MW 1 and MW5. Ethylbenzene and xylenes were <br /> ' detected in the soil sample collected at 25 feet below grade from boring MW2 at <br /> concentrations of 0.024 mg/kg and 0.073 mg/kg, respectively, and benzene was detected at <br /> a concentration of 0 041 mg/kg in the soil sample collected from boring MW2 at a depth <br /> ' of 30 feet below grade immediately above first encountered groundwater. BTEX were <br /> detected in the soil sample collected from boring MW3 at a depth of 25 feet below grade <br /> at concentrations of 0 34 mg/kg benzene, 12 mg/kg toluene, 2 7 mg/kg ethylbenzene, and <br /> ' 14 6 mg/kg xylenes, and at 30 feet below grade collected immediately above first <br /> encountered groundwater at concentrations of 0.59 mg/kg benzene, 0 083 mg/kg <br /> ethylbenzene, and 0.2 mg/kg xylenes BTEX were detected in the soil sample collected <br /> ' from boring MW4 at a depth of 25 feet below grade at concentrations of 0 58 mg/kg <br /> benzene, 0 51 mg/kg ethylbenzene, and 2 9 mg/kg xylenes, at 30 feet below grade collected <br /> immediately above first encountered groundwater at concentrations of 0.082 mg/kg benzene, <br /> ' 0 088 mg/kg ethylbenzene, and 2 9 mg/kg xylenes, and a saturated soil sample at 40 feet <br /> below grade approximately 8 feet below the first encountered groundwater level at <br /> concentrations of xylenes at 0 011 mg/kg <br /> iiiaicai 12 <br /> 1 <br />