6' - 0" MAX, TYP. <br /> I I GC TO PROVIDE 2" MIN <br /> PLASTIC GROMMET <br /> (2) #10 X 1.5" vO <br /> WOOD SCREWS, <br /> TYP. O v <br /> A` 1/2" GYP BD <br /> + PENDANT LIGHT FIXTURE ©2011 STARBUCKS COFFEE <br /> SUPPORT OR SIMILAR <br /> SUPPORT <br /> STARBUCKS COFFEE <br /> (E) ROOF (E) ROOF <br /> FRAMING FRAMING ` COMPANY <br /> CJ PENDANT LIGHT FIXTURE OR 2401 UTAH AVENUE SOUTH <br /> 4" X 18 GA. STEEL BRACING �� SIMILAR PENETRATION <br /> AT 48" O.C. (PROVIDE CONT. , SEATTLE, WASHINGTON 98134 <br /> BRIDGING W/2-#10 SCREW TO (206) 318-1575 <br /> EA. BRACE WHEN BRACE IS <br /> MORE THAN 12'-0" IN LENGTH). THESE DRAWINGS AND SPECIFICATIONS ARE <br /> CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> PROPERTY OF STARBUCKS CORPORATION,WHICH IS <br /> THE OWNER OF THE COPYRIGHT IN THIS WORK. <br /> PLASTIC GROMMET THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN <br /> 4" X 18 GA. STEEL PART), SHARED WITH THIRD PARTIES OR USED IN AN <br /> 4" X 18 GA. STEEL BRACING STUDS@ 16" OC MANNER ON OTHER PROJECTS OR EXTENSIONS TO W/4#10 SCREWS <br /> AT 48" O.C. (PROVIDE CONT. scale: 1/4" = 1'-0" THIS PROJECT WITHOUT THE PRIOR WRITTEN <br /> BRIDGING W/2410 SCREW TO TO (E) JOISTS. 5/8" GYP. BD, TYP CONSENT OF STARBUCKS CORPORATION. THESE <br /> EA. BRACE WHEN BRACE IS DRAWINGS AND SPECIFICATIONS ARE INTENDED TO <br /> MORE THAN 12'-0" IN LENGTH). TWO (2) NO. 12 GAUGE WIRES MUST BE LATERAL FORCE BRACING MEMBERS MUST BE EXPRESS DESIGN INTENT FOR A PROTOTYPICAL <br /> j SECURED FROM LIGHT & MECHANICAL SPACED A MIN OF 6" FROM ALL HORIZONTAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE <br /> FIXTURES AT OPPOSING CORNERS PIPING OR DUCT WORK THAT IS NOT PROVIDED AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE <br /> ALONG THE FIXTURE'S DIAGONAL. -------- -----__ W/BRACING RESTRAINTS FOR HORIZ FORCES. CONDITIONS. NEITHER PARTY SHALL HAVE ANY <br /> U WIRES MAY BE SLACK. BRACING WIRES MUST BE ATTACHED TO THE OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT <br /> �I GRID &TO THE STRUCTURE IN SUCH A MANNER STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS <br /> NOTE: ---------� THAT THEY CAN SUPPORT A DESIGN LOAD OF FULLY EXECUTED BY BOTH PARTIES. <br /> FOUR NO. 12 GAUGE WIRES MUST BE NOT LESS THAN 200 POUNDS OR THE ACTUAL <br /> SECURED TO THE MAIN RUNNER WITHIN 2" LOAD, WHICHEVER IS GREATER, WITH A SAFETY <br /> >_ 4" X 18 GA. STEEL BRACING OF THE CROSS RUNNER INTERSECTION FACTOR OF 2. ARCHITECT OF RECORD <br /> AND SPLAYED 90 DEGREES FROM EACH U <br /> oZS AT 48" O.C. (PROVIDE CONT. <br /> i 4" X 18 GA LEDGER + 4"X 18 GA + 4" X 18 GA OTHER AT AN ANGLE NOT EXCEEDING 45 <br /> W/ (2) #10 X 3" LONG BRIDGING W/2 #10 SCREW TO LIGHT FIXTURE G > _ • <br /> + BLOCKING, TYP EA. BRACE WHEN BRACE IS + BLOCKING, TYP DEGREES FROM THE PLANE OF THE > o — <br /> ? WOOD SCREWS AT + MORE THAN 12'-0" IN LENGTH). + CEILING. (MAY BE SLACK) (LESS THAN 56 LBS) <br /> EACH (E) STUD, TYP. N <br /> C) d + e NO. 12 GAUGE -- IN.40 <br /> ------- <br /> co WIRES WITHIN 3" OF ----------- -� 3" MAX <br /> T a <br /> ALL 4CORNERS. AT mcg architecur <br /> X 111 Pacifica, Suite 280, Irvin, CA 92618 <br /> m OPPOSITE CORNERS OF SUPPORT P:949.553.1117 F:949.474.7056 <br /> � / WIRES, OR SCREW ON T-BAR NOTE: <br /> I ' ' / 4" X 18 GA. STEEL STUDS AT 16" PROVIDE EARTHQUAKE <br /> N #10 SMS AT EACH (4) #10 SMS. SAFETY CLIPS AT SIDES OR ENDS. <br /> M SIDE AND EACH STUD. TYP. O.C. WITH 4 -#10 SCREWS, TYP CLIPS &WIRES AS REQ'D. ARCHITECT STAMP <br /> rn SEE 1/I-1107 FOR �� aR <br /> _ 5/8" GYP. BD, TYP HEIGHT OF SOFFIT SUSPENDED Wr <br /> T <br /> U) <br /> W <br /> CEILING GRID n <br /> S yk <br /> ti <br /> °C 1 SOFFIT DETAIL 7 CEILING LIGHT DETAIL pU"E'2019�a,� <br /> 0 scale: 1 1/2"= 1'-0" <br /> Scale: 3/8" = 1'-0" <br /> F <br /> U <br /> M VERTICAL STRUT @ 12" O.C. MAX. EACH <br /> COMPRESSION STRUT GUIDELINES <br /> v WAY WITH FIRST POINT TO BE WITHIN 6" NOTE: <br /> Q FROM EACH WALL FASTENED TO MAIN 8 GA HANGER WIRE TO VERIFY ASSEMBLY WITH TRUSS COMPRESSION STRUT SIZE MAXIMUM LENGTH <br /> Np RUNNER & STRUCTURE ABOVE @ 4'-0" MFG WHERE 1 HR ASSEMBLY IS <br /> STRUCTURE ABOVE PER ASCE-7 13.5.6.2.2 A OC NW/4 WIRES SPLAYED 90 REQ'D 3/4" DIAMETER STRUT 12'-0" <br /> p deg IN 4 DIRECTIONS (45° <br /> Cz 12 GAo XQ MAX FROM CEILING PLANE) 1" DIAMETER STRUT 18'-0" <br /> . VERTICALID 2 1/2"x 20 GAUGE METAL STUD (I MIN. = 0.18") 11' 6" LL1 <br /> U EACH ER WIRE AT 4'-0' 90o� 90o t f • TYPE "S" SCREW <br /> I WAY WITH MIN. 3 TIGHT MAX @ 8 OC TOGETHERBACK-TO-BACK <br /> @ 24" O Cx 20 GAUGE METAL STUD SCREWED <br /> 15'-0" <br /> v TURNS 1-1/2"AT BOTH 20 GAUGE 2 <br /> ENDS OF WIRE (TYP.) U FURRING HEAVY DUTY T-BAR SYSTEM <br /> O o <br /> CHANNEL @ 12 GA WIRE HANGER @ PER ASTM AC 635 & ASTM AC -- 48" O.C. W co <br /> � <br /> �I0 636. SEC 1613.1 CBC. EA. WAY. FIRST POINT TO BE 8" rn (o <br /> 24"OC / FROM WALL. L0 <br /> CROSS RUNNERS N / <br /> T _ VERTICAL COMPRESSION STRUT O Q <br /> E o AND BRACING WIRES @ 12'-0"O.C. <br /> W o MAX. EACH WAY. FIRST POINT TO 0 Z U <br /> } Cn <br /> Q <br /> c <br /> fi fi o BE WITHIN 6'-0" FROM EACH WALL. LU O <br /> g a A FASTENER TO MAIN RUNNER & 06 <br /> 06 ° X LO � o 20 GAUGE WIRE o S"2j STRUCTURE ABOVE WITH 1/4" < z Q <br /> 0 2" � D� q� MACHINE BOLTS. SEE NOTE 4. z z Q D U <br /> 0 MAIN RUNNERS 1 1/2" 20 GAUGE �P� 2" MAXWIRES TO CROSS TEES. FROM BRACING W LU <br /> /// COLD ROLLED U U <br /> C) X STEEL @ 48" OC W <br /> co 12 GA. BRACING WIRE WITH MIN. — Q 8" MAX <br /> BRACING WIRES TO BE ATTACHED Q Z Q m00 Q <br /> 4 TIGHT TURNS IN 1-1/2"AT 6'-0" 12'-0"OC 5/8" FIRE-RATED 1 . @ MAX OF 45 DEGREES. MIN OF 4 � � N <br /> r BOTH ENDS OF WIRE (TYP.) AT / D- D- r <br /> GYP, ALL EDGES TIGHT TURNS IN 1-1/2" @BOTH <br /> X EACH VERTICAL STRUT P <br /> m MAX 75 AT TWO ADJACENT SUPPORTED v o x ENDS OF ALL BRACING WIRE TYP. <br /> �I LO <br /> NOTES: WALLS. SEE NOTE 2 5 GYPSUM BOARD D ETA I L X rr STORE #: 11830 <br /> MAIN RUNNER @ 4'-0" O.C. <br /> N REFLECTED CEILING PLAN Scale: 1/4" = 1' o" PROJECT #: 37913-049 <br /> 1. SUSPENDED ACOUSTICAL CEILING SYSTEM SHALL BE <br /> p INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF SHIM AS NEEDED LARK#25764 CASEWORK CONCEPT: CORE <br /> U) ASTM C 635 AND ASTM C 636. <br /> ICC ER#1222 ISSUE DATE: <br /> Y LINE OF WALL CROSS TEE @ 2'-0" O.C. PROGRAM MANAGER: M.DREBIKA <br /> () 2. BRACING WIRES SECURED TO MAIN RUNNERS WITHIN 2"OF OR 1' 0" O.C. AS SHOWN <br /> THE CROSS RUNNER INTERSECTION AND SPLAYED 90° FROM 6'-0" MAX. 6'-0" MAX. STORE DESIGNER: T.MARINIC <br /> m o 12' - 0" MAX. 12' - 0" MAX. ATTACHMENT CLIP NOTES: <br /> 00 EACH OTHER AT AN ANGLE NOT EXCEEDING 45 FROM THE LEEDOAP: N/A <br /> PLANEOF THE CEILING 1. ALL 24"X48" CEILING LIGHT FIXTURES & 24"X24" HVAC AIR REGISTERS SHALL BE <br /> < 8" MAX 8" MAX CHECKED BY: <br /> MAIN T GRID (USG SUPPORTED BY A MINIMUM OF (2) HANGERS @ OPPOSITE CORNERS. CEILING SYSTEM SHALL <br /> U) 3. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF NOT SUPPORT OTHER ITEMS. MCG PROJECT#: 19232 <br /> p THE CEILING GRID SHALL BE ATTACHED TO A MINIMUM 2"WIDE DX26, MCG PROJ. MANAGER: C.LEE <br /> C) BLACK COLOR) <br /> CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL w w 2. ALL INTERIOR WALL& CEILING FINISHES SHALL BE INSTALLED TO CLASS III FLAME SPREAD. MCG PROJ. SPECIALIST: SPARK <br /> 4 <br /> j DIRECTION SHALL HAVE 0.75" CLEARANCE FROM THE WALL AND U) ~O so NO. 12 GA MIN <br /> SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE z VERTICAL HANGER 3. 45 DEGREE BRACE WIRES & COMPRESSION STUDS ARE TO BE PROVIDED ONLY IF <br /> o ANGLE. A WIRE, SEE NOTE 3 REQUIRED BY LOCAL BUILDING DEPARTMENT. Revision Schedule <br /> rn 4. WHEN THE DISTANCE BETWEEN THE STRUCTURAL DECK AND = > ', 4. COMPRESSION STRUTS : STEEL SECTION ATTACH TO MAIN RUNNERS WITH 1/4" MACHINE Rev Date By Description <br /> r THE CEILING EXCEEDS 4", THE SPACING OF THE VERTICAL 0 ACOUSTICAL TILE BOLT AND TO STRUCTURE WITH 3/16" DIAMETER POWER DRIVEN STUD. COMPRESSION STRUT <br /> N HANGERS SHALL NOT EXCEED 2'O.C. ALONG THE ENTIRE MEANS m: CEILING ON SUSPENDED .75"AT TWO SHALL NOT REPLACE HANGER WIRE. <br /> OF EGRESS SERVICING THE OCCUPANT LOAD OF 30 OR MORE, GRID SYSTEM ADJACENT WALLS <br /> AND AT LOBBIES ACCESSORY TO GROUP A OCCUPANCIES. = SEE NOTE 2 5. BRACING WIRES SECURED TO MAIN RUNNERS WITHIN 2" OF THE CROSS RUNNER <br /> Ln <br /> — COMPRESSION STRUT CEILING PANEL INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING <br /> 75 5. EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATER z_ 45 DEGREES FROM THE PLANE OF THE CEILING. <br /> Q DEFLECTIONS, SPRINKLER HEADS AND OTHER PENETRATIONS, <br /> SHOW A 2" OVERSIZED RING, SLEEVE OR ADAPTER THROUGH — I MIN WALL ANGLENSTALLED 1/4" BELOW MAIN <br /> ( 6. CLOSURE ANGLE SHALL BE A MINIMUM OF 2". SHEET TITLE: <br /> THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST (I <br /> � 1" IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY A SWING GRID) 7. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN CEILING DETAILS <br /> 0 <br /> JOINT THAT CAN ACCOMMODATE 1" OF CEILING MOVEMENT IN SECTION THROUGH ROOM PROVIDE COMPLETE 2" IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE <br /> r ALL HORIZONTAL DIRECTIONS IS PERMITTED TO BE PROVIDED AT INSTALLATION AS RECOMMENDED ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION <br /> rn THE TOP OF THE SPRINKLER HEAD EXTENSION. PER ASCE 7-05, BY MANUFACTURER AND CODES SHALL HAVE A 0.75" CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO I SCALE:AS SHOWN <br /> CD SEC 13.5.6.2.2. <br /> SLIDE ON A CLOSURE ANGLE. <br /> N SHEET NUMBER: <br /> co <br /> 13 TYPICAL SUSPENDED CEILING VERTICAL & LATERAL SUPPORT 46 T-BAR TO WALL DETAIL j) T-BAR CEILING DETAIL 1505 <br /> r scale: 1/8"= 1'-0" scale: 6" = 1'-0" scale: 1/4 = 1 -0 <br />