GENERAL NOTE POWER PLAN NOTES SHEET NOTES <br /> 1. REUSE EXISTING ELECTRICAL PANELS AND RECONNECT THE A. FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM.ALL O PROVIDE CONNECTION FOR POS BANK. FIELD COORDINATE FOR EXACT <br /> RELOCATED LOADS AS REQUIRED. IF NEW LOADS ARE ADDED, ITEMS ARE NOT NECESSARILY SHOWN. 1 <br /> USE AVAILABLE SPARE CIRCUITS. LOCATION AND REQUIREMENT. EXTEND EXISTING WIRING FOR <br /> B. ELECTRICAL CONTRACTOR RESPONSIBLE FOR SITE PREVIOUSLY USED THE SAME TYPE OF EQUIPMENT IN EXISTING DEMO 17' <br /> 2. FIELD VERIFY THE RATINGS OF THE EXISTING PANELS AND INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL LOCATION TO THIS NEW LOCATION. CONNECT TO CIRCUIT AS SHOWN. <br /> AVAILABLE SPARE CAPACITIES. IF NEW LOADS ARE ADDED TO SCOPE OF WORK. <br /> THE PANEL DO NOT EXCEED THE RATING OF THE PANEL O2 PHONE LINE. FIELD COORDINATE EXACT LOCATION. <br /> INCLUDING THE RATINGS OF THE UPSTREAM SERVING C. DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. <br /> FEEDER AND CIRCUIT BREAKER. O PROVIDE CONNECTION FOR REGISTER. FIELD COORDINATE EXACT <br /> D. REFER TO DETAIL SHEETS FOR EXACT LOCATIONS AND MOUNTING LOCATION AND REQUIREMENT. EXTEND EXISTING WIRING FOR <br /> 3. ALL CIRCUIT NUMBERS SHOWN HERE ARE BASED ON HEIGHTS OF ELECTRICAL DEVICES. PREVIOUSLY USED THE SAME TYPE OF EQUIPMENT IN EXISTING DEMO <br /> PROVIDEDRECORD DRAWING. IF THE ACTUAL EXISTING CIRCUIT LOCATION TO THIS NEW LOCATION. CONNECT TO CIRCUIT AS SHOWN. ©2017 STARBUCKS COFFEE COMPANY <br /> NUMBERS ARE DIFFERENT THAN THE ONES SHOWN HERE, USE E. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR <br /> THE ACTUAL NUMBERS AND PROVIDE UPDATED TYPEWRITTEN CONFIRMING ALL VOLTAGE REQUIREMENTS ON ALL EQUIPMENT �4 EXISTING ELECTRICAL PANEL TO REMAIN. FIELD VERIFY EXACT <br /> SCHEDULE IN ALL PANELS USED IN THIS PROJECT. AND PROVIDING BUCK-BOOST TRANSFORMERS AS MAY BE LOCATION. PROVIDE UPDATED TYPEWRITTEN SCHEDULE UPON STARBUCKS COFFEE <br /> NEEDED FOR PROPER OPERATION OF THE EQUIPMENT.ALL ARE COMPLETION OF THIS PROJECT. SEE PANEL SCHEDULE ON SHEET E-601. <br /> NOT NECESSARILY INDICATED. MAINTAIN 36"CLEARANCE IN FRONT OF PANELS. COMPANY <br /> F. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH PLUMBING O EXISTING POS TO BE RELOCATED HERE AND RE-CONNECTED TO 2401 UTAH AVENUE SOUTH <br /> AND HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) EXISTING CIRCUIT PREVIOUSLY USED FOR SAME EQUIPMENT. SEATTLE, WASHINGTON 98134 <br /> CONTRACTORS FOR ANY ADDITIONAL EQUIPMENT NEEDING O ALL 120V RECEPTACLES IN WORKROOM AND BAR AREA SHALL BE GFCI (206) 318-1575 <br /> POWER. 6 <br /> RATED. AND ALL SINGLE PHASE RECEPTACLES RATED 150 VOLTS TO <br /> G. ANY EQUIPMENT NOTED AS 'FUTURE' SHALL BE PROVIDED WITH GROUND OR LESS, 50A OR LESS AND THREE PHASE RECEPTACLES RATED THESE DRAWINGS AND SPECIFICATIONS ARE <br /> APPROPRIATE RECEPTACLES AND WIRING TO ENABLE FUTURE 150 VOLTS TO GROUND OR LESS, 100A OR LESS INSTALLED IN THE CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> OPERATION. FOLLOWING LOCATIONS SHALL HAVE GROUND FAULT CIRCUIT PROPERTY OF STARBUCKS CORPORATION, <br /> INTERRUPTER PROTECTION FOR PERSONNEL. WHICH IS THE OWNER OF THE COPYRIGHT IN <br /> H. GROUND FAULT CIRCUIT INTERRUPTER (GFCI) BREAKERS (NOT THIS WORK. THEY SHALL NOT BE <br /> RECEPTACLES) SHALL BE UTILIZED WHERE REQUIRED BY CODE O EXISTING UNDERCOUNTER FRIDGE TO BE RELOCATED HERE. FIELD REPRODUCED (IN WHOLE OR IN PART), SHARED <br /> AND AT ANY FLOOR BOXES. PROVIDE DEDICATED NEUTRAL WIRE COORDINATE EXACT LOCATION AND REQUIREMENT. IF POSSIBLE, EXTEND WITH THIRD PARTIES OR USED IN ANY MANNER <br /> FOR ALL THESE CIRCUITS. THE EXISTING CIRCUIT PREVIOUSLY USED FOR THE SAME LOAD IN THIS ON OTHER PROJECTS OR EXTENSIONS TO THIS <br /> AREA. IF NO SUCH CIRCUIT IS AVAILABLE, PROVIDE NEW CONNECTION TO PROJECT WITHOUT THE PRIOR WRITTEN <br /> I. DISCONNECT AND REMOVE EXISTING ELECTRICAL DEVICES FOR IT. CONSENT OF STARBUCKS CORPORATION. <br /> EXISTING EQUIPMENT TO BE REMOVED. REROUTE CONDUIT AND THESE DRAWINGS AND SPECIFICATIONS ARE <br /> CONDUCTORS AROUN WALLS AND CEILING AFFECTED BY Og EXISTING BLENDER TO BE RELOCATED HERE. FIELD COORDINATE EXACT INTENDED TO EXPRESS DESIGN INTENT FOR A <br /> REMODEL SO THAT DOWN STEAM DEVICES TO REMAIN STAY LOCATION AND REQUIREMENT. IF POSSIBLE, EXTEND THE EXISTING PROTOTYPICAL STARBUCKS STORE (WHICH IS <br /> POWERED. REMOVE PORTIONS NO LONGER REQUIRED BACK TO CIRCUIT PREVIOUSLY USED FOR THE SAME LOAD IN THIS AREA. IF NO SUBJECT TO CHANGE AT ANYTIME)AND DO <br /> NEAREST JUNCTION BOX OR TO SOURCE. TRACE ALL CIRCUITS IN SUCH CIRCUIT IS AVAILABLE, PROVIDE NEW CONNECTION TO IT. NOT REFLECT ACTUAL SITE CONDITIONS. <br /> THE AFFECTED AREAS PRIOR TO CONSTRUCTION AND RE-LABEL NEITHER PARTY SHALL HAVE ANY OBLIGATION <br /> PANELS ACCORDINGLY. O EXISTING BREWER SOFT HEAT SERVER/SINGLE WARMING STAND TO BE NOR LIABILITY TO THE OTHER (EXCEPT STATED <br /> RELOCATED HERE. FIELD COORDINATE EXACT LOCATION AND ABOVE) UNTIL A WRITTEN AGREEMENT IS <br /> J. WORKING CLEARANCES SHALL BE MAINTAINED AND ARE SUBJECT REQUIREMENT. IF POSSIBLE, EXTEND THE EXISTING CIRCUIT PREVIOUSLY FULLY EXECUTED BY BOTH PARTIES. <br /> TO FIELD VERIFICATION PER NEC 110.16. USED FOR THE SAME LOAD IN THIS AREA. IF NO SUCH CIRCUIT IS <br /> AVAILABLE, PROVIDE NEW CONNECTION TO IT. <br /> K. GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION SHALL ARCHITECT OF RECORD <br /> BEINSTALLED IN KITCHENS PER NEC 210.8(B)(2). SUBJECT TO 10 EXISTING BREWER SOFT HEAT DUAL TO BE RELOCATED HERE. FIELD mcg architecture <br /> FIELD VERIFICATION. COORDINATE EXACT LOCATION AND REQUIREMENT. IF POSSIBLE, EXTEND • <br /> THE EXISTING CIRCUIT PREVIOUSLY USED FOR THE SAME LOAD IN THIS <br /> U C C <br /> L. GROUND-FAULT CIRCUIT-INTERRUPTER SHALL BE INSTALLED IN A AREA. IF NO SUCH CIRCUIT IS AVAILABLE, PROVIDE NEW CONNECTION TO <br /> READILY ACCESSIBLE LOCATION PER NEC 210.8. SUBJECT TO IT C-) <br /> FIELD VERIFICATION. <br /> 11 EXISTING GRINDER DITTING/DIGITAL SCALE TO BE RELOCATED HERE. <br /> M. SIGNS AND OUTLINE LIGHTING SYSTEM EQUIPMENT FOR WET FIELD COORDINATE EXACT LOCATION AND REQUIREMENT. IF POSSIBLE, <br /> LOCATION USE, OTHER THAN LISTED WATERTIGHT TYPE, SHALL EXTEND THE EXISTING CIRCUIT PREVIOUSLY USED FOR THE SAME LOAD 111 Pacifica, Suite 280, Irvine,CA 92618 <br /> BE WEATHERPROOF AND HAVE DRAIN HOLES, AS NECESSARY, IN IN THIS AREA. IF NO SUCH CIRCUIT IS AVAILABLE, PROVIDE NEW P: 949.553.1117 F:949.474.7056 <br /> ACCORDANCE WITH THE FOLLOWING: DRAIN HOLES SHALL NOT BE CONNECTION TO IT. <br /> PANEL"A" LARGER THAN '/2 INCH OR SMALLER THAN '/4 INCH. EVERY LOW <br /> �titititititititi1 <br /> 18 E 13620 4 POINT OR ISOLATED SECTION SHALL HAVE AT LEAST ONE DRAIN PROVIDE CONNECTION FOR FUTURE MOBILE ORDER, PAY& PRINTACTES ^�RpFESS�p�11it <br /> PANEL"B" HOLE; DRAIN HOLES SHALL HAVE NO EXTERNAL OBSTRUCTIONS. LABELER. FIELD COORDINATE EXACT LOCATION AND REQUIREMENT. Yrrr��OQS�Am Z.cq�Ftz <br /> N. CALIFORNIA ELECTRICAL CODE REQUIRES THE SERVICE 13 PROVIDE CONNECTION FOR NEW FOOD CASE. FIELD COORDINATE EXACT ENGINEERING r�wo� 9��czttzj <br /> EQUIPMENT'S MAIN DISCONNECT SWITCH AND FUSE, OR THE 3371 Olcott Street l <br /> LOCATION AND REQUIREMENT. IF POSSIBLE, EXTEND THE EXISTING . 15130 A 1 <br /> CIRCUIT BREAKER, TO BE RATED AT THE AVAILABLE CIRCUIT PREVIOUSLY USED FOR THE SAME LOAD IN THIS AREA. IF NO Santa Clara,CA 95054 ! j <br /> SHORT-CIRCUIT CURRENT VALUE. ALL NEW NON-RESIDENTIAL, SUCH CIRCUIT IS AVAILABLE, PROVIDE NEW CONNECTION AND CONNECT ph:(408)522 5255 2 .p' /w/2o * r <br /> INDUSTRIAL AND MANUFACTURING ARE SUPPLIED BY AN fx:(408)522-5260 2 s p Q r <br /> r <br /> 17 �fo <br /> - INDIVIDUAL SERVICE DROP OR LATERAL RATED AT 225 AMPS OR TO CIRCUIT AS SHOWN. info@acies.net tt21�9 ZFCTRXG <br /> MORE ARE REQUIRED TO HAVE A FAULT CURRENT LETTER 14 PROVIDE CONNECTION FOR NEW ESPRESSO MACHINE. FIELD Copyrght©2019 ttltf OF Cp``Fp'�Nr <br /> 6 PROVIDED BY PG&E OR THE ELECTRICAL SERVICE PROVIDER tittititititititi��� <br /> COORDINATE EXACT LOCATION AND REQUIREMENT. IF POSSIBLE, EXTEND <br /> 17 E 18029 THE EXISTING CIRCUIT PREVIOUSLY USED FOR THE SAME LOAD IN THIS <br /> O. EQUIPMENT INTENDED TO BREAK CURRENT AT FAULT LEVELS AREA. IF NO SUCH CIRCUIT IS AVAILABLE, PROVIDE NEW CONNECTION <br /> A-(34,36) _ SHALL HAVE AN INTERRUPTING RATING SUFFICIENT FOR THE AND CONNECT TO CIRCUIT AS SHOWN. <br /> 2#10+1#10G— SYSTEM VOLTAGE AND THE CURRENT WHICH IS AVAILABLE AT <br /> 16 E 12407 A-(34 6) 3/4"C. O THE LINE TERMINALS OF THE EQUIPMENT. THERE ARE TWO WAYS 15 PROVIDE CONNECTION FOR NEW HOT WATER DISPENSER. FIELD <br /> 1� m I/ m � I � 25'-0"FIXED SEATING TO SATISFY THE CODE REQUIREMENT: EITHER SERIES RATED OR COORDINATE EXACT LOCATION AND REQUIREMENT. IF POSSIBLE, EXTEND <br /> N1 11 FULLY RATED. ANY NEW BREAKERS OR SUB-PANELS MUST MEET THE EXISTING CIRCUIT PREVIOUSLY USED FOR THE SAME LOAD IN THIS <br /> A-(22 lgi� <br /> 4) THIS REQUIREMENT. AREA. IF NO SUCH CIRCUIT IS AVAILABLE, PROVIDE NEW CONNECTION <br /> P. GC TO NOTIFY SBUX CM + DM IF THERE ARE ANY(E) FLOOR AND CONNECT TO CIRCUIT AS SHOWN. W <br /> 7A-(22,24) OUTLETS THAT NEED TO BE RELOCATED OR REMOVED. PROVIDE CONNECTION FOR NEW WARMING OVEN. FIELD COORDINATE <br /> or 2#10+1#10G <8> <br /> /4"C. Q. EQUIPMENT REQUIRES CONNECTION TO THE BUILDING EXACT LOCATION AND REQUIREMENT. IF POSSIBLE, EXTEND THE <br /> EXISTING CIRCUIT PREVIOUSLY USED FOR THE SAME LOAD IN THIS AREA. <br /> 12 A-2 ( (❑) (❑) (❑ (❑) �) _ <br /> ELECTRICAL SYSTEM. FURNISH AND INSTALL ALL NECESSARY <br /> e IF NO SUCH CIRCUIT IS AVAILABLE, PROVIDE NEW CONNECTION AND W <br /> CONDUIT, WIRE, CONNECTIONS, RECEPTACLES AND <br /> �O (� A-28,30 OVERCURRENT PROTECTION NECESSARY TO ENSURE THE CONNECT TO CIRCUIT AS SHOWN. <br /> EQUIPMENT FUNCTIONS PROPERLY AND COMPLIES WITH ALL PROVIDE CONNECTION FOR NEW ICE MACHINE. FIELD COORDINATE U) <br /> E: 2 2 2 2 2APPLICABLE LOCAL AND NATIONAL CODES. COORDINATE 17 <br /> EQUIPMENT REQUIREMENTS WITH MANUFACTURER CUT SHEET EXACT LOCATION AND REQUIREMENT. IF POSSIBLE, EXTEND THE O <br /> EA-( 30) E 16238 13 PRIOR TO ROUGH-IN. EXISTING CIRCUIT PREVIOUSLY USED FOR THE SAME LOAD IN THIS AREA. Q <br /> IF NO SUCH CIRCUIT IS AVAILABLE, PROVIDE NEW CONNECTION AND z f , <br /> 11R. ALL FRONT BAR J-BOXES AND OUTLETS SHALL BE SURFACE CONNECT TO CIRCUIT AS SHOWN. LU <br /> O. <br /> 6 MOUNTED. PROVIDE CONDUITS AS NEEDED AND ONE (1) 06 <br /> 10ADDITIONAL SPARE CONDUIT BETWEEN ALL J-BOXES FOR FUTURE 18 PROVIDE CONNECTION FOR NEW REACH-IN FRIDGE. FIELD COORDINATE 0 z U <br /> ELECTRICAL REQUIREMENTS. ALL J-BOXES SHALL BE POSITIONED EXACT LOCATION AND REQUIREMENT. IF POSSIBLE, EXTEND THE z z Q <br /> TO AVOID OBSTRUCTION OF ANY EQUIPMENT SUCH AS EXISTING CIRCUIT PREVIOUSLY USED FOR THE SAME LOAD IN THIS AREA. LLI <br /> C DREFRIGERATORS AND DISHWASHERS. IF NO SUCH CIRCUIT IS AVAILABLE, PROVIDE NEW CONNECTION AND U O U <br /> 9 CONNECT TO CIRCUIT AS SHOWN. W W W.0 z <br /> S. REFERENCE LANDLORD WORK LETTER FOR DIVISION OF -3 <br /> 1 3 ELECTRICAL SCOPE OF WORK AND COORDINATE WITH 19 PROVIDE CONNECTION TO NEW BLENDER PITCHER. FIELD COORDINATE 0 Z 0 CV <br /> 65 ❑ STARBUCKS CONSTRUCTION MANAGER. EXACT LOCATION AND REQUIREMENTS. W d <br /> c� <br /> 5 2 A-(6,8 T. DATA CABLING LOCATED ABOVE HEAD SHALL BE PLENUM. <@> PROVIDE CONNECTION TO NEW NITROGEN GENERATOR ELEMENT. FIELD <br /> COORDINATE EXACT LOCATION AND REQUIREMENTS. STARE #; 11830 <br /> 2#6+1 0 U. DATA CABLING LOCATED UNDERGROUND SHALL BE RATED FOR <br /> 5 - E 19742 14 3/4"C. BELOW GROUND USE. PROVIDE CONNECTION TO NEW KEG DISPENSING SYSTEM. FIELD PROJECT #: 37913-049 <br /> 1 3 COORDINATE EXACT LOCATION AND REQUIREMENTS. <br /> A 1 A-(14,16) PROFILE TYPE: CORE <br /> 7 #6+1#10GQ PROVIDE RECEPTACLE IN BANQUETTE UNIT AND CONNECT TO THE ISSUE DATE: <br /> A-18 3/4"C. • EXISTING CIRCUIT IN THE AREA. FIELD COORDINATE EXACT LOCATION <br /> A-13 A-1 P 15749 15 00 AND REQUIREMENTS. PROGRAM MANAGER: M.DREBIKA <br /> 20010 A-1 A-7 A-2 STORE DESIGNER: T.MARINIC <br /> 19559 l� 12 ( ) � IF THERE IS NO EXISTING OUTLET CLOSE BY THIS LOCATION, THEN LEED®AP: N/A <br /> A 19,21 PROVIDE NEW OUTLET AS SHOWN AND CONNECT TO THE NEAREST <br /> A-20 2 2 6+1#10G CHECKED BY: <br /> AVAILABLE CIRCUIT. FIELD COORDINATE EXACT LOCATION AND <br /> 19 E 7 64 -� <br /> 1 E 19742 14 3/ C REQUIREMENTS. ACIES PROJECT#: 190478 <br /> p` 2 A-(23ACIES PROJ. MANAGER: HT <br /> 8 6 7 2#6+1, 5) <br /> 15 L L L ACIES PROJ. SPECIALIST: TG <br /> 7 P 15749 3/4"C. <br /> Revision Schedule <br /> A-2 12 O <br /> Rev Date By Description <br /> A-2 A-4 <br /> r` 4 3 <br /> OR A-4 - <br /> SHEET TITLE: <br /> ELECTRICAL <br /> <7 > 3 3 POWER DESIGN <br /> 1 Power Plan SCALE: AS SHOWN <br /> Scale: 1/4" = 1'-0" SHEET NUMBER: <br /> E-103 <br />