My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 2:27:53 PM
Creation date
5/7/2020 9:58:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
410
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N 10 A Q U I N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCO 06080 85 E LOUISE AVE, LATHROP January 29,2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 113 CCR 2638(d)Failed to submit monitoring system certification test report within 30 days. <br /> Annual monitoring system certification,leak detector testing,and spill container testing was performed on 2/1/2017 <br /> and a test report was submitted passed 30 days. A copy of the test report must be submitted within 30 days of the <br /> tests. Take all necessary precautions to ensure testing and submittal of test reports are performed in a timely <br /> manner. <br /> This is a minor violation. <br /> 121 CCR 2712(f)Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 2/1/2017 and an inspection report was issued identifying information to be submitted <br /> to bring this site into compliance. This information was required to be submitted by 2/31/2017. An operator that <br /> receives an inspection report shall have 30 days to submit a written response that includes a statement <br /> documenting corrective actions taken or proposing corrective actions which will be taken. Ensure that a written <br /> response documenting corrective actions taken or proposed is submitted within 30 days of receiving an inspection <br /> report. <br /> This is a Class II violation. <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions. <br /> The S11 Vacuum sensor was replaced on 1/11/2018 and a permit was not obtained from the EHD. Emergency <br /> repairs relating to UST system monitoring and release detection may be performed by a properly licensed,trained, <br /> and certified contractor pursuant to the EHUS policy and a permit obtained within one business day from the EHD. <br /> All other repairs must have a permit submitted to and approved by the EHD prior to beginning work. Immediately <br /> obtain a permit from the EHD for the replacement of the S11 Vacuum sensor. A"Failure to Obtain a Permit'penalty <br /> applies. <br /> This is a minor violation. <br /> 304 HSC 25290.1(d)Monitoring system not maintained to detect entry into secondary containment(after Jul 2004). <br /> The dispenser#3/4 208 sensor failed to activate an audible and visual alarm when tested to ensure continuous <br /> monitoring of the tank system. All monitoring equipment shall be maintained to activate an audible and visual alarm <br /> or stop the flow of product at the dispenser when it detects a leak. The sensor was replaced and retested during the <br /> inspection by the technician. A"UST Retrofit Verification with Inspector Already Onsite"form has been completed <br /> and provided to the operator and contractor. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 313 HSC 25290.1,25290.2,25291 Failure to construct,operate, and maintain primary containment as product-tight. <br /> Weepage was observed on the diesel pipe in the dispenser#4, indicating a leak in the primary piping. All primary <br /> containment for the UST system must be tight. Immediately have a properly licensed,trained, and certified <br /> contractor repair or replace the failed component under permit and inspection of the EHD. <br /> This is a repeat violation, Class II. <br /> FA0003635 PR0231656 SCO01 01/29/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.