COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 2:27:53 PM
Creation date
5/7/2020 9:58:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
410
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REr,EIVED <br /> San Joaquin County MAR 0 7017 <br /> Environmental Health Department END D <br /> 1868 East Hazelton Avenue, Stockton, Califo p� rllatt� <br /> � MENTAL HEA 17 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 �nnivw aiaex tzraNT S -1 I <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> ARCO 06080 (209) 983-9144 February 01, 2017 <br /> Facility Address: CERS ID: <br /> 85 E LOUISE AVE, LATHROP, CA 95330 10181263 <br /> Inspection Contact: Title: Phone: <br /> Karen Wolfe Manager (209) 983-9144 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit —72351 - UST FACILITY-2481 COMPLIANT <br /> Consent For: Consent Given By: <br /> El Inspection N Photos I] Samples I Karen Wolfe, Manager <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Gilbert Garcia 07/01/2017 Kaylynn Rammell 06/15/2018 <br /> Service Technician Manufacturer's Training <br /> Veeder Root,03/15/17; VMI, 09/27/18 <br /> CCR=California Codeo egu a ions HSC=Health and Safety Code CFR=Codeo a eral Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate o V u R ❑COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system ❑V n R o COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted a V u R o COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current n V ❑R o COS <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan ❑V u R ❑COS <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan n V n R ❑COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed u V n R o COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing n V ❑R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment u V ❑R o COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days ❑V ❑R ❑COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually u V o R ❑COS <br /> 112 HSC 25284.2 Failed to test spill containers annually o V ❑R ❑COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days n V ❑R o COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down a V a R ❑COS <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operator identification or change within 30 days ❑V o R ❑COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification u V ❑R o COS <br /> 117 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after ❑V ❑R o COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests n V ❑R ❑COS <br /> 119 HSC 25299 Documents were falsified or misrepresented ❑V o R ❑COS <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification u V u R n COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report ❑V ❑R a COS <br /> 122 CCR 26310) Failure to submit UST system component statement of compatibility for substance stored ❑V ❑R o COS <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions ❑V u R o COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years o V o R o COS <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair,lining,and upgrades on site ❑V u R n COS <br /> FA0003635 PR0231656 SC001 02/01/2017 <br /> EHD 23-01 Rev.09/22/16 Page 1 of 5 Underground Storage Tank Program OIR <br />