My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 2:27:53 PM
Creation date
5/7/2020 9:58:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
410
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GEIVED <br /> San Joaquin County <br /> Environmental Health Department MAR 0 2 2016 <br /> 1868 East Hazelton Avenue, Stockton, California95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:mm-siUov.orgleho ENVIRONMENTAL <br /> UC, r1Cp9nTtRCrI <br /> Underground Storage Tank Program Inspection Report <br /> !TLl <br /> Facility Mame: Facility Address: <br /> Date: <br /> UST System Observations <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br /> uV ❑R :j COS <br /> 322 CCR 2636(0(2) Line leak detector not installed <br /> _ __ ❑V o R o COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi <br /> oV o ❑COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty <br /> o V o R o COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum Capacity of five gallons <br /> r.V u R Li COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements <br /> ❑V c,R o COS <br /> 327 CCR 2635(b)(2) Overfill prevention was overridden <br /> c o uCOS <br /> 328 HSC 25283.5 Unburied below grade UST failed to meet exemption status <br /> oV uR aCOS <br /> 329 CCR 2717.1(g) Tampered with red tag <br /> a V o R o COS <br /> 330 CCR 2717.1(1) Deposited petroleum into a red tagged UST <br /> oV o oCOS <br /> 331 HSC 25289(f)(2) Tampered with or disabled leak detection devices or alarms <br /> 0 u oCO3 <br /> 332 CCR 2631.1 UST system not compatible with the substance stored <br /> oV o nC05 <br /> 333 HSC 25298(b) Failed to comply with temporary closure requirements <br /> riV 0 oCOS <br /> 334 HSC 25298(c) Failed to comply with permanent closure requirements <br /> aV eR nGOS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not property sloped or Incorrectly located check valve <br /> cV 0 nCOS <br /> 402 CCR 2643(d) Daffy monitoring of suction pipe(pre-Jan 1984)not performed <br /> ❑V o R a COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test forconventional suction piping not performed(pre-January 1984) a V o R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) <br /> n nR ❑COS <br /> voter V101atibns <br /> 2010 See below Unlisted Administration/Documentation violation <br /> cV ❑R ACOS <br /> 2030 See below Unlisted Operations/Maintenance violation <br /> oV aR oCOS <br /> 2060 See below Unlisted Design/Construction violation <br /> oV nR rCOS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br /> Paqe 3 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.