My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 2:27:53 PM
Creation date
5/7/2020 9:58:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
410
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UST Program: Tank Informa Permit Application: CERS Business Pagel of <br /> California Environmental Reporting System;Business Sian_1QFEP. <br /> ?Ovi ,I I W.Horne Submittals Facilities Comp" Ld.— W. <br /> UST Tank Information/Monitoring Plan: ARCO 06080 MAR 0 2 2016 <br /> 6 f 10_-Lau— <br /> $�I, )) js� <br /> lastruaborrwHelp ENVIRONMENTAL <br /> Use this form to enter data for new LIST systems or revise data for an existing LIST system You must complete a separate form for each affected tank.For tanks&�9905 PTA.9 I=Ni-r <br /> compartmentalized unit,each compartment is considered a separate tank This information is required within 30 days of permit or facility information changes,unless your local <br /> agency requires approval prior to making the changes. <br /> Select Edit to modify/add your LIST tankf"em information <br /> The former paper version of this form was ralled"UST Operating Parrr*Application-Tank Information"(Form B). <br /> ubmittal Element History— <br /> Submitted for GERS 10 10181263 on 2t3r2016 8:34AM by Nicole Ma,gn of BP West Coast Products LLC-Retail(Carson) <br /> Comments by submitter.MARKED PREMIUM AND DIESEL AS"ONE IN A COMPARTMENTED UNIT"AND LISTED THE NUMBER OF COMPARTMENTS IN <br /> THE UNIT AS"2"PER INSPECTOR'S REQUEST NO OTHER CHANGES MADE TO UST SECTION. <br /> Submittal was Acceptaidon 2/1812016 by NG,MLLYfor Safi joaquin County Environmental Health <br /> Comments by regulator:This LIST submittal was received but not reviewed by Wily Ng,REHS,ICC Certified LIST Inspector.on February 18,2016.This <br /> submittal is subject to verification at the next scheduled field inspection. <br /> Vlekv 1711tile su:dnitldl Start f-k",Submittal <br /> -J <br /> Monitoring Man <br /> Type of Action- <br /> Type of Action JUST'tank) <br /> ConfirmeciMpdated Information <br /> --Facility Information --- <br /> ARCO 06080 <br /> 85 E LOUISE AVE <br /> LATHROP, CA 95330 <br /> -Tank Descriptiorr— <br /> Tank 10# Date UST System Installed Tank Configuration <br /> TA0519982 31I7/2011 One in a Compartmented Unit <br /> Tank Manufacturer Date E.I.IlIng UST Discovered Number of Compartments an the Unit <br /> OWENS CORNING 2 <br /> Tank Capacity In Gallons Date UST Permanently Closed Additional Description <br /> 10000 <br /> Tank Use and Contents------- Tank Construction—_-- <br /> Tank Use Tank Contents Type of Tank <br /> Motor Vehicie Fueling Diesel Double Wali <br /> Other Petroleum Contents <br /> Primary Containment Secondary Containment <br /> Other Non.Petvoleurn Contents Fiberglass Fiberglass <br /> Overfill Protection <br /> Yes AudibleNtsuall Alarms No Fill Tube Shut-OH valve <br /> Yes Bell Float NO Exempt <br /> -Product I WastePiping Construction----- <br /> Piping Construction <br /> Primus"Containment Secondary Containment Pipingrrurbine Containment Sump <br /> Double-walled Fiberglass Fiberglass I Double-walled <br /> Piping System Type <br /> Pressure <br /> -Vent,Vapor Recovery IVR)and Riser/Fill Pipe Piping Construction- <br /> Vent Primary Containment Vapor Recovery Primary Containment Riser Pipe Primary Containment Vent Piping Transltlori Sumps <br /> Fiberglass Nor* Steel None <br /> Fill Components Installed <br /> Vent Secondary Containment Vapor Recovery Secondary Containment Riser Pipe Secondary Containment Yes Spill Bucket <br /> Fiberglass None Fiberglass <br /> Yes Striker PlatetBottorn Protector <br /> Yes Containment Stamp <br /> [-Under Dispenser Containment JUDC1— <br /> https://cersbusiness.calepa.ca.gov/45294/Facility/10181263/Submittal/UST/1502604/Tank... 2/19/2016 <br />
The URL can be used to link to this page
Your browser does not support the video tag.