My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0009248
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TOSTE
>
2353
>
2900 - Site Mitigation Program
>
PR0231735
>
ARCHIVED REPORTS_XR0009248
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2020 9:37:40 AM
Creation date
5/8/2020 9:24:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0009248
RECORD_ID
PR0231735
PE
2381
FACILITY_ID
FA0003778
FACILITY_NAME
TRACY MARINE SALES
STREET_NUMBER
2353
STREET_NAME
TOSTE
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
02
SITE_LOCATION
2353 TOSTE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> IQuarterly Report - Third Quarter 2002 <br /> • TRACY MARINE SALES <br /> 2353 Toste Road, Tracy, California <br /> 1.0. INTRODUCTION <br /> I At the request of Mr Joe Toste, Jr , Advanced GeoEnvironmental, Inc (AGE) has prepared this <br /> quarterly report for the property located at 2353 Toste Road, Tracy, California The site and the <br /> surrounding area are illustrated in Figure 1 On-site structures,boring locations and monitoring well <br /> I locations are illustrated on Figure 2 Background information is summarized in the AGE-prepared <br /> Additional Site Assessment Work Plan, dated 26 September 2000 <br /> I2.0. PROCEDURES <br /> I Eleven ground water monitoring wells (MW 1 through MW 11) were purged and sampled in <br /> September 2002 Field work was performed in accordance with guidelines issued by the Central <br /> Valley Regional Water Quality Control Board (CVRWQCB) for the investigation of underground <br /> Istorage tank (UST) sites <br /> I2 1 WELL MONITORING AND EVACUATION <br /> On 26 September 2002, a Sohnst water level meter was used to measure the depth to ground water <br /> Iin eleven wells (MWI through MW11) relative to the tops of the well casings The ground water <br /> elevations and gradient were determined from these data(Table 1) <br /> IAfter recording water level measurements, disposable plastic bailers were used to purge the wells <br /> of standing water Approximately 6 0 to 6 5 gallons of water(a minimum of 3 casing-water volumes <br /> I per well) were removed from wells MWI, MW3, MW7, MW9, MW10 and MW11 Monitoring <br /> well MW6 was purged of approximately 13 gallons of water and approximately 3 0 gallons of water <br /> were removed from wells MW2,MW4,MW5 and MW8 before the wells were pumped dry Ground <br /> water temperature,pH and conductivity were measured at regular intervals during purging using an <br /> Oakton water analyzer Field sheets and data are included in Appendix A Purged water was stored <br /> on-site in labeled, 55-gallon Department of Transportation (DOT)-approved drums <br /> I <br /> 2 2 COLLECTION AND ANALYSIS OF GROUND WATER SAMPLES <br /> IWater samples were collected from the purged wells using new disposable plastic bailers after <br /> allowing the wells to achieve a minimum 80%recovery of the pre-purge water volume Each water <br /> I <br /> i <br /> I <br /> I <br />