My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0010609
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
14749
>
2900 - Site Mitigation Program
>
PR0507155
>
ARCHIVED REPORTS_XR0010609
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2020 11:09:46 AM
Creation date
5/8/2020 9:58:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0010609
RECORD_ID
PR0507155
PE
2950
FACILITY_ID
FA0007718
FACILITY_NAME
3 B'S TRUCK PLAZA
STREET_NUMBER
14749
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
Zip
95242
APN
05515026
CURRENT_STATUS
02
SITE_LOCATION
14749 N THORNTON RD
P_DISTRICT
004
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Quarterly Report - August 1999 <br /> THREE B'S TRUCK PLAZA <br /> 14749 Thornton Road, Lodi, California <br /> 1.0. INTRODUCTION AND SCOPE OF WORK <br /> Advanced GeoEnvironmental, Inc (AGE) has prepared this Quarterly Report for 14749 Thornton <br /> Road,Lodi, California The site setting is illustrated on Figure I Site structures and monitoring well <br /> locations are depicted on Figure 2 <br /> IThe objective of the work was to monitor dissolved petroleum hydrocarbon concentrations in ground <br /> water and to characterize ground water flow direction and gradient on the site This report is <br /> I prepared in accordance with guidelines established by the San Joaquin County Public Health <br /> Services - Environmental Health Division (PHS-EHD) and by the Central Valley Regional Water <br /> Quality Control Board (CVRWQCB) for investigation of underground storage tank (UST) sites A <br /> summary of previous investigations at the site was included in the Preliminary Site Investigation and <br /> Evaluation Report - November 1996, dated 20 June 1997 and prepared by AGE Analytical data <br /> acquired to date is included in this report <br /> I <br /> . 2 0. QUARTERLY MONITORING AND SAMPLING PROCEDURES <br /> I On 13 August 1999 round water monitoring/sampling. rocedures were performed at wells MW-1 <br /> g � gP <br /> through MW-6 Grab ground water samples were collected from the domestic drinking water well <br /> located in a southwest section of the site in August, September and November 1999 Ground water <br /> monitoring procedures for the site were outlined in Work Plan Addendum - October 1998, dated 14 <br /> October 1998 prepared by AGE and approved by the PHS-EHD by letter dated 21 December 1998 <br /> I21 MONITORING WELL PURGE PROCEDURES <br /> Depths to ground water were measured in each well from the tops of the well casings at the site to <br /> Ithe nearest 0 01 foot utilizing a Solinst water level meter Ground water elevations in each well at <br /> the site were calculated by subtracting the measured depth to ground water fiom surveyed casing <br /> elevations (Table 1) Ground water elevations were plotted and contoured on a scaled site map <br /> (Figure 3) <br /> I After water levels were measured,approximately 3 to 6 gallons of ground water(a minimum of three <br /> well-volumes per well) were removed from wells MW-1 through MW-6 utilizing a teflon hand <br /> bailer Temperature, pH and conductivity were measured for stabilization at regular purge-volume <br /> I intervals from each well using an ICM Model 52200 water analyzer Field data and logs are included <br /> with Appendix A Purged ground water was containerized in 55-gallon drums and was stored on-site <br /> in an area lacking general public access <br /> Advanced GeoEnvironmental,Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.