Laserfiche WebLink
1 <br />' 10 November 2003 <br /> . AGE-NC Project No 97-0249 <br />' Page 6of8 <br /> TBA was detected In 3 ground water samples collected from wells MW-1, MW-8A and MW-11A <br /> at concentrations as high as 56�tg/l, 1,2-DCA was detected in 4 ground water samples collected from <br /> wells MW-2, MW-6, MW-l0A and MW-11A at concentrations as high 6 9 µg/1 <br />' No other fuel components were detected in the ground water samples Previous and current analytical <br /> results of ground water monitoring well samples are summarized In Tables 3 and 4 The laboratory <br /> reports(McCampbell Analytical Inc Work OrderNos 0309280,0309318 and 0309344)and chain- <br /> of-custody forms are presented in Appendix C Analytical ground water data for the Flag City <br /> Chevron's monitoring events are included in Appendix B <br />' <br /> 4.0. SUMMARY AND CONCLUSIONS <br />' The implications from the September 2003 ground water monitoring event are as follows <br />' • Generally,depth to ground water at the site vaned between 12 and 15 feet bsg, ground water <br /> elevations ranged between 4 93 feet(MW-11B and MW-11E) and 5 36 feet(MW-5)below <br /> mean sea level <br />' • Ground water in Hydrogeologic Unit 1 at the Three B's Truck Plaza site was inferred to be <br /> east and oriented towards a ground water depression in the area of Flag City Chevron wells <br /> MW-1, MW-2 and MW-4 (Figure 4) <br /> • Ground water in Hydrogeologic Units 2, 3 and 4 at the Three B's Truck Plaza was inferred <br /> to be eastwardly and oriented towards a ground water depression in the area of Flag City <br /> Chevron wells MW-6 and MW-9 (Figure 5, 6 and 7) <br /> • Ground water in Hydrogeologic Unit 6 at the Three B's Truck Plaza and Flag City Chevron <br /> were inferred to towards the east-southeast (Figure 8) <br />' • The most intense TPH-g impacted ground water was reported in the area of wells MW-2, <br /> MW-3 and MW-6 at concentrations as high as 12,000 µg/l (Figure 9) <br />' • The most intense TPH-d impacted ground water was reported in the area of wells MW-2, <br /> MW-3, MW-6 and MW-8A at concentrations as high as 860 µg/1 (Figure 10), an isolated <br /> TPH-d occurrence was reported at Flag City Chevron well MW-12A <br />' • The most intense on-site MTBE-impacted ground water was detected from Hydrogeologic <br /> Unit i in the in the area of Three B's Truck Plaza well MW-8A at a concentration of 110 <br />' �Lg/1 (Figure 11), from Hydrologic Unit 2 in the area of Three B's Truck Plaza well MW-9A <br /> at a concentration of 13 µg/l(Figure 12), and from Hydrogeologic Unit 3 in the area of Flag <br /> City Chevron wells MW-11B and MW-18 at concentrations as high as 120 µg/1 <br />' (Appendix A) <br />' Advanced CcoEnvironmental,Inc <br /> t <br />