Laserfiche WebLink
9255517888 Line 13:07:37 03-10-2014 12/17 <br /> cf 1t' A53/A53M — 12 <br /> 0.04 In. <br /> t=specified wall thickness 1i0�mlr <br /> �0" <br /> 9DEPTH DEPTH <br /> hAAX 10%t,±15% <br /> WITH MIN OF <br /> 0.012 ±0.002 in. <br /> 21LESS 10.3+ 0.05 mm] <br /> LENGTH <br /> B (BUTTRESS) NOTCH FOR EDDY CURRENT—1.5 in.138 mm] MAX <br /> Totol Length <br /> 60° FOR DIVERTED FLUX <br /> rMAX--/ AND ULTRASONIC — 2 in. [50 mm] MAX <br /> of Full Depth <br /> 10% t N 10 NOTCH <br /> ORf'LESS <br /> V 10 NOTCH <br /> mmj <br /> 20% t <br /> OLESS <br /> AREA OF EACH SIDE , 0.006 in?[3.9mm2] MAX <br /> P (PARALLEL SIDED) NOTCH DRILLED HOLE <br /> FIG.1 Calibration Standards <br /> TABLE 3 Acceptance Limits detection of differently oriented imperfections. Ultrasonic test- <br /> Type Notch Size of Hole Acceptance ing is not necessarily capable of detecting short, deep iniper- <br /> in. mm Limit fections. <br /> Signal,% <br /> Nto,vto is s.2 100 9.2.2.3 The eddy current examination referenced in this <br /> B,P 80 specification has the capability of detecting significant discon- <br /> tinuities, especially of the short abrupt type. <br /> 9.2.2.4 The flux leakage examination referred to in this <br /> specification is capable of detecting the presence and location <br /> 9.2 Type S Pipe—As an alternative to the hydrostatic test at of significant longitudinally or transversely oriented disconti- <br /> the option of the manufacturer or if specified in the purchase nuities. The provisions of this specification only require <br /> order, the full body of each seamless pipe shall be tested with longitudinal calibration for flux leakage. Different techniques <br /> a nondestructive electric test in accordance with Practice E213, need to be employed for the detection of differently oriented <br /> E309, or E570. In such cases, each length so furnished shall imperfections. <br /> include the mandatory marking of the letters"NDE."Except as 9.2.2.5 The hydrostatic test referred to in 8.2 has the <br /> allowed by 9.2.6.2,it is the intent of this nondestructive electric capability of finding imperfections of a size permitting the test <br /> test to reject pipe with imperfections that produce test signals fluid to leak through the tube wall and may be either visually <br /> equal to or greater than those produced by the applicable seen or detected by a loss of pressure.Hydrostatic testing is not <br /> calibration standards. necessarily capable of detecting very tight through-the-wall <br /> 9.2.1 If the nondestructive electric test has been performed, imperfections or imperfections that extend an appreciable <br /> the lengths shall be marked with the letters "NDE." The distance into the wall without complete penetration. <br /> certification, if required, shall state Nondestructive Electric 9.2.2.6 A purchaser interested in ascertaining the nature <br /> Tested and shall indicate which of the tests was applied.Also, (type, size,location, and orientation) of imperfections that are <br /> the letters NDE shall be appended to the product specification capable of being detected in the specific application of these <br /> number and grade shown on the certification. examinations is directed to discuss this with the manufacturer <br /> 9.2.2 The following information is intended to facilitate the of the tubular product. <br /> use of this specification: 9.2.3 For ultrasonic testing, the calibration reference <br /> 9.2.2.1 The calibration standards defined in 9.2.3 through notches shall be at the option of the manufacturer,and shall be <br /> 9.2.5 are convenient standards for calibration of nondestructive any one of the three corrunon notch shapes shown in Practice <br /> testing equipment.The dimensions of such standards are not to E213. The depth of notch shall not exceed 12.5% of the <br /> be construed as the minimum sizes of imperfections detectable specified wall thickness of the pipe or 0.004 in. [0.1 mm], <br /> by such equipment. whichever is the greater. <br /> 9.2.2.2 The ultrasonic testing referred to in this specification 9.2.4 For eddy current testing, the calibration pipe shall <br /> is capable of detecting the presence and location of significant contain, at the option of the manufacturer, any one of the <br /> longitudinally or circumferentially oriented imperfections; following calibration standards to establish a minimum sensi- <br /> however, different techniques need to be employed for the tivity level for rejection. <br /> Copyright by ASTM 1nt'l(all rights reserved);Tue Nov 6 09:27:19 EST 2012 5 <br /> Downloaded/printed by <br /> Received Time""Mar.. 10. si12 014at 12: 5 3 P MAN o, 5384 further reproductions authorized. <br />