Laserfiche WebLink
9255517888 Line 13:10:24 03-10-2014 15/17 <br /> c ' A53/A53M - 12 <br /> 15. Test Methods 17.3 Weight (Mass) per Unit Area of Coating Test-The <br /> 15.1 The test specimens and the tests required by this weight(mass)per unit area of zinc coating shall be determined <br /> specification shall conform to those described in the latest issue by stripping tests in accordance with Test Method A90/A90 M. <br /> of Test Methods and Definitions A370• 17.4 Test Specimens-Test specimens for determination of <br /> 15.2 Each longitudinal tension test specimen shall be taken weight (mass) per unit area of coating shall be cut approxi- <br /> from a pipe end and shall not be flattened between the gage mately 4 in. [100 mm] in length. <br /> marks. 17.5 Number of Tests-Two test specimens for the determi- <br /> 15.3 Test specimens for bend tests and flattening tests shall nation of weight(mass)per unit area of coating shall be taken, <br /> be taken from pipe.Test specimens for flattening tests shall be one from each end of one length of galvanized pipe selected at <br /> smooth on the ends and free from burrs. random from each Jot of 500 lengths, or fraction thereof, of <br /> 15.4 Tests shall be conducted at room temperature, each size. <br /> 17.6 Retests-If the weight (mass) per unit area of coating <br /> 16. Lengths of any lot does not conform to the requirements specified in <br /> 1-11.2,retests of two additional pipes from the same lot shall be <br /> 16.1 Unless otherwise specified, pipe lengths shall be in made, each of which shall conform to the specified require- <br /> accordance with the following regular practices: ments. <br /> 16.1.1 Except as allowed by 16.1.2 and 16.1.4, pipe lighter <br /> than extra-strong weight shall be in single-random lengths of 17.7 If pipe ordered under this specification is to he galva- <br /> 16 to 22 ft[4.88 to 6.71 m],with not more than 5%of the total nized, the tension, flattening, and bend tests shall be made on <br /> number of threaded lengths furnished being jointers (two the base material before galvanizing, if practicable. If speci- <br /> pieces coupled together). fied, results of the mechanical tests on the base material shall <br /> 16.1.2 For plain-end pipe Iighter than extra-strong weight,it be reported to the purchaser. If it is impracticable to make the <br /> shall be permissible for not more than 5 % of the total number mechanical tests on the base material before galvanizing, it <br /> of pipe to be in lengths of 12 to 16 ft [3.66 to 4.88 m]. shall be permissible to make such tests on galvanized samples, <br /> 16.1.3 Pipe of extra-strong weight or heavier shall be in and any flaking or cracking of the zinc coating shall not be <br /> random lengths of 12 to 22 ft [3.66 to 6.71 m], except that it considered cause for rejection. If galvanized pipe is bent or <br /> shall be permissible for not more than 5% of the total of pipe otherwise fabricated to a degree that causes the zinc coating to <br /> to be in lengths of 6 to 12 ft [1.83 to 3.66 m]. stretch or compress beyond the limit of elasticity, some flaking <br /> 16.1.4 For extra-strong weight or lighter pipe ordered in of the coating is acceptable. <br /> double-random lengths, the minimum lengths shall be not less 18. Inspection <br /> than 22 ft [6.71 m] and the minimum average length for the <br /> order shall be not less than 35 ft [10.67 m]. 18.1 The inspector representing the purchaser shall have <br /> 16.1.5 For pipe heavier than extra-strong weight ordered in entry, at all times while work on the contract of the purchaser <br /> lengths longer than single random, the lengths shall be as is being performed, to all parts of the manufacturer's works <br /> agreed upon between the manufacturer and the purchaser. that concern the manufacture of the pipe ordered. The manu- <br /> 16.1.6 If pipe is furnished threaded and coupled, the length facturer shall afford the inspector all reasonable facilities to be <br /> shall be measured to the outer face of the coupling. satisfied that the pipe is being furnished in accordance with this <br /> specification.All tests(except product analysis) and inspection <br /> 17. Galvanized Pipe shall be made at the place of manufacture prior- to shipment, <br /> 17.1 Galvanized pipe ordered under this specification shall unless otherwise specified, and shall be so conducted as not to <br /> be coated with zinc inside and outside by the hot-dip process. interfere unnecessarily with the operation of the works. <br /> The zinc used for the coating shall be any grade of zinc <br /> conforming to Specification B6. 19. Rejection <br /> 17.2 Weight (Mass)per Unit Area of Coating-The weight 19.1 The purchaser is permitted to inspect each length of <br /> (mass)per unit area of zinc coating shall be not less than 1.8 pipe received from the manufacturer and,if it does not meet the <br /> oz/ft2[0.55 kg/m2] as determined from the average results of requirements of this specification based upon the inspection <br /> the two specimens taken for test in the manner prescribed in and test method as outlined in the specification,the length shall <br /> 17.5 and not less than 1.6 oz/ft2[0.49 kg/M2] for each of these be rejected and the manufacturer shall be notified. Disposition <br /> specimens. The weight (mass) per unit area of coating, ex- of rejected pipe shall be a matter of agreement between the <br /> pressed in ounces per square foot[kilograms per square metre] manufacturer and the purchaser, <br /> shall be calculated by dividing the total weight(mass)of zinc, 19.2 Pipe found in fabrication or in installation to be <br /> inside plus outside,by the total area,inside plus outside,of the unsuitable for the intended use, under the scope and require- <br /> surface coated. Each specimen shall have not less than 1.3 ments of this specification, shall be set aside and the manufac- <br /> oz/ft2[0.40 kg/m2] of zinc coating on each surface, calculated turer notified. Such pipe shall be subject to mutual investiga- <br /> by dividing the total weight(mass)of zinc on the given surface tion as to the nature and severity of the deficiency and the <br /> (outside or inside)by the area of the surface coated (outside or forming or installation, or both, conditions involved. Disposi- <br /> inside). tion shall be a matter for agreement. <br /> Copyright by ASTM Infl(all rights reserved);Tue Nov 6 09:27:19 EST 2012 8 <br /> Downloaded/printed by <br /> Re e e v e d Ti m e"'M a r. 10. s`2 014u'12; 5 3 p M AN o, 5 3 84'further reproductions authorized. <br />