igGfrrcER-RYAN Ikc. GR Job # 20-600050 <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 330.01 <br /> Complete the following checklist: <br /> Yes o Is the audible alarm operational? <br /> Yes No' Is the visual alarm operational? <br /> r, Yes No' Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> Yes No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> roper operation? <br /> Yes No' If alarms are relayed to a remote monitoring station,is all communication equipment(e.g.modem)operational? <br /> WA <br /> Yes No' For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment monitoring system <br /> N/A detects a leak,fails to operate,or is electrically disconnected?If yes:which sensors initiate positive shut-down?(Check all that apply) <br /> E Sump/Trench Sensor; r3 Dispenser Containment Sensor.Did you confirm positive shutdown due to leaksnn sensor <br /> failure/disconnection? Yes; (] No. <br /> Yes No' For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no mechanical overfill prevention <br /> N/A valve is installed),is the overfill warning alarm visible and audible at the tank fill points)and operating properly?If so,at what percent <br /> of tank capacity does the alarm trigger? 90 % <br /> r& Yes 0 No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E,below. <br /> r& Yes 0 No Was liquid found inside any secondary containment systems designed as dry systems?(Check all that apply) []Product; []Water. if <br /> yes,describe causes in Section E,below. <br /> Yes No' Was monitoring system set-up reviewed to insure proper settings?Attach set-up reports,if applicable. <br /> Yes ❑ No' Is all monitoring equipment operational per manufacture's specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Replaced sensors (794380-304) on UDC's 1/2, 3/4, &7/8 <br /> All 794380-304 sensors @ fill sumps, STP sumps, Vent box& UDC were tested & Pass <br /> Remove water from Diesel fill sump &87 fill sump <br /> Overfill external alarm failed- Replaced fuse at Veeder Root. Tedted and Pass. <br /> Monitoring System Certification Page 2 of 4 12/07 <br /> 2 <br />