SAN.JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209) 468-3420 Fax:(209)468-3433 Web:www.sagov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Arco Station #6080 Facility Insp85 East Louise Ave, Lathrop Date: Feb <br /> Feb 18, 2014 <br /> Name: Address: <br /> VIOLATIONS <br /> # C7 C2 M Code Section HSC=CA Health and Safe Code,CFR=Code of Federal Regulations <br /> C1=Class 1 violation.C2=Class 2 violation,M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (Mt) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (Mt) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> UST Inspection: Routine & Annual Monitoring System Certification <br /> Class II/ Repeat violations#: 402 Minor. 314, 406 <br /> 402. Fuel was found at the diesel STP sump, on both side of the saddle, that would total approximately a <br /> cup, insufficient amount to trigger the liquid detection sensors. An absorbent pad was placed down into <br /> the liquid by the technician to confirm it was diesel. Approximately less than one gallon of liquid was <br /> removed from vent sump by technician. No liquid was observed in the 91 STP but can see old residue of <br /> where fuel would have settled. <br /> Several times, Gettler Ryan technicians had to remove liquid from vent, 91 STP and diesel STP sumps. <br /> -Work order ticket#9921039, date 013014, technician Alex C, had documented "Removed liquid in vent <br /> sump and dsl STP. Found to be condensation/ rain water." <br /> -Work order ticket#C203074, date 012914, technician Wes Morrison, had documented "Removed liquid <br /> from Diesel STP and premium STP & vent sump" <br /> -Work order#9901137, date 073013, unknown technician, receipt was documented "water in sump of <br /> vent" <br /> -Work order#9902495, date 072513, technician M. Pratt, had documented "pumped out liquid out diesel <br /> STP sump" <br /> All primary containment must be impervious to the liquid or vapor of the substance contained. <br /> Immediately have a properly licensed, trained and certified contractor replace or repair the failed piping <br /> under permit and inspection of EHD. Ensure 91 STP, diesel STP and vent sumps are liquid tight and find <br /> source of leakage. Diesel flex hose was replaced back on April 2013. If the failed component can't be <br /> replaced immediately, there is a possibility that the 91 and diesel UST system maybe red tagged to <br /> prevent fuel inputs. <br /> 314. The ATG/ tank probes used as audible/visual alarm on the overfill prevention system is not <br /> currently functional on the whole UST system. No audible & visual alarm was heard externally although <br /> the Veeder-Root system was able to display the overfill alarm on the display & printout. The tester on <br /> the external box device was able to produce the audible sound. The blown fuse inside the Veeder-Root <br /> module was replaced. <br /> - Probes retested at 90% of tank capacity, passed with audible & visual alarms. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector: Receive y Title <br /> EHD 23-0 Rev 04/19/12 P ge 3 UST INSPECTION REPORT <br />