My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2012 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2020 4:03:34 PM
Creation date
5/8/2020 11:48:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2015
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installation lnsrallalion Proceduro Installation Field Ihridi;g Con i- <br /> 5. Push the end of the cable into the box cord grip port labeled mini-hydrostatic Sensor and straight into the box <br /> until the end reaches the terminal block labeled MINI-HYDROSTATIC SENSOR ONLY.Strip back the ends of <br /> the cable jacket and wires as shown in Figure 3. <br /> 1-2' <br /> I IE-3/8' <br /> oCad I <br /> Figurea. Stripping cable jacket and two conductor arida <br /> I <br /> 6. Push down either one of the two white terminal release levers in the back of the terminal black and insert one O <br /> of the two stripped wires into the terminal opening in the front of the block then release the lever.Tug gently on <br /> the wire to make sure it is secured in the terminal.Check to see that the end of the cable jacket is inside the <br /> box(see Figure 4).Note:observing polarity is not necessary for any of these connections.Push down the <br /> other white release lever on the terminal block and insert the second wire.Again pull on the wire to check that <br /> it too is secure. <br /> 7. Pull any excess cable out of the box,then tighten the cord grip to seal the cable entry into the box. <br /> S. Attach the connector end of the Position Sensitive or Sump Sensors cable to the lop of the sensor.Coil up <br /> and tie wrap any excess cable.Get the cord grip bushing and nut from the sensor kit and slide them over the <br /> end of the sensor cable(tapered end of bushing toward unit). <br /> 9. Push the end of the cable into the box cord grip poll beside the just finished Mini-Hydrostatic Sensor cord Figure 1, Ati.WN g ceWu b Sam-Input Box Termlmb <br /> grip and straight into the box until the end reaches the terminal block labeled PAN/SUMP SENSOR ONLY. Legend for numbered boxes In Figure 2 <br /> Strip back the ends of the cable jacket and wires as shown in Figure 3. <br /> 1. Position sensitive or sump sensor corvxscta to PAN/SUMP SENSOR ONLY lertrinal dock <br /> 10.Push down either one of the two white terminal release levers in the back of the terminal block and insert one 2. Cable(connects to TLS console cable in skmpjunction box) <br /> of the two stripped wires into the terminal opening in the front of the block then release the lever.Tug gently on 3. Push down lever and insert wire end(typJ <br /> the wire to make sure it is secured in the terminal.Note:observing polarity is not necessary for any of these 4. Mini-hydrostatic sensor connects to MINI-HYDROSTATIC SENSOR ONLY temenal block <br /> connections.Push down the other while release lever on the terminal block and insert the second wire then 5. Make sure end of cable jacket is well inside box to ensure weatherproof seal(typ.) <br /> release the lever.Tug gently on the wire to make sure it is secured in the terminal. 6. Mini-hydrostatic sensor cable enters this cord grip port(see cover label) <br /> 11.Pull any excess cable out of the box,then tighten the cord grip to seal the cable entry into the box. 7. Position sensitive or sump sensor cable enters this cord grip port(see cover label) <br /> 12.Apply a coating of petroleum jelly to the Sensor Input Box cover o-ring and screw the cover down securely. 6. ATG terminal block <br /> The Sensor Input Box installation procedure is now complete. <br /> Field Wiring Connectlons <br /> 1. Open the sump junction box.If necessary,pull a shielded 2-conductor cable from the TLS console into tho <br /> sump's junction box.Refer to the TLS3XX Site Prep manual(P/N 576013-879)or the TLS-4XX Site Prep <br /> manual(P/N 577013-879)as applicable for the approved size and type cable that can be used for Veeder- <br /> Root sensors. <br /> 2. Strip back the ends of the cable jacket and wires of the TLS console cable as shown in Figure 3. <br /> 3. Get a cord grip bushing and nut from the installation kit.Slide the tapered end of the bushing into one of the <br /> sump junction box fittings and loosely screw on the cord grip nut.Push the end of the cable from the Sensor <br /> Input Box into the loosened cord grip and into the junction box. <br /> 4. Connect the Sensor Input Box cable to the TLS console cable in the junction box using the two wire nuts in <br /> the kit(see Figure 5).Note:you do not have to observe polarity for these connections. <br /> 5 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.