My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2004 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 11:54:19 AM
Creation date
5/8/2020 4:22:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2007
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
384
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002Page 5 of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer Xlndustry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum Hydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used: tyj 40finci 0,7 5 Equipment Resolution: <br /> Sump# fp,,�/e Sump Vilpi Sump# Sump# - <br /> "Depth: <br /> yi <br /> Sump Material- ti man <br /> Height from T&nk Top to Top of <br /> Highest Piping Penetration: Z 3 <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: 16 <br /> Condition of sump prior to testing: <br /> Portion of Sump Tested wt, h;a6v 1 rm. U It 0 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both 0 Yes ❑No Ns[A 0 Yes ❑No /' /"'❑Yes ❑No NA ❑Yes 0 No ' <br /> r•oduct and water?' ` <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe ❑Yes (I No l &A 0 Yes ❑No XM ❑Yes ❑No k9NA ❑Yes ❑No `�INA <br /> shutdown?' <br /> Was fail-safe verified to be 0 Yes ❑No 9IA ❑Yes 0 No �NA ❑Yes ❑No )4,NA ❑Yes ❑No NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 3o 011 n �( <br /> test: •% <br /> Test Start Time: 3 ,5 y �, <br /> Initial Reading(Rr): !G.-/7 2"� /�_ 17 2 3 G <br /> Test End Time: Al, c 57 q/.` 2 3 <br /> Final Reading(RF): ;r. �� fE'- /'7 z z Z <br /> Test Duration: <br /> Change in Reading(RF-RD: 0CIO /y <br /> Pass/Fail Threshold or Criteria: 0 0,W 0,0012- <br /> Test Result: X Pass. 0 Fail' .Pass :`:p Fa� 0 Pass QFar1 q Pass , gFail >;. <br /> Was sensor removed for testing? Yes 0 No ❑NA XYes 0 No ❑NA �Yes ❑No ❑NA >TYes 0 No ❑NA <br /> Was sensor properly replaced and Yes 0 No ❑NA <br /> verified functional after testing? JKYes 0 No [INA rYes ❑No [INA XYes ❑No ❑NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> If the entire depth of the sump is not tested,specify how much was tested If the answer to Aff of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested_ (See SWRCB LG-160) <br /> Arco # 06080 <br /> 85 E. Louise Avenue <br /> Lathrop, CA 95330 <br /> N05115- SB 989 Testing <br />
The URL can be used to link to this page
Your browser does not support the video tag.