Laserfiche WebLink
Enseco <br /> . A Coming Company <br /> I Sample Description <br /> See the attached Sample Description Information. <br /> The samples were received under - <br /> p chain-of custody. <br /> IIAnalysis Request <br /> The following analytical 'tetts were requested. <br /> Lab ID Analysis Description <br /> 055128-1 thru 3 Total Petroleum Hydrocarbons <br /> Total ;Petroleum Hydrocarbons (Gasoline) <br /> III Quality Control <br /> A. Project Specific OL. No project specific QC (i .e. , spikes and/or <br /> duplicates) was requested. <br /> B. Method Blank Results. A method blank is a laboratory-generated <br /> sample which assesses the degree to which laboratory operations <br /> and procedures cause false-positive analytical results for your <br /> samples. <br /> No target parameters were detected 9 p d in the method blanks associated <br /> with your samples at the reporting limit levels noted' on the <br /> attached Method Blank Report. <br /> C. Laboratory- ControlSamples =' The US Program <br /> Duplicate Control Samples. A DCS is a well_characterized matrix <br /> (blank water, sand -or celite) which is spiked with certain target <br /> parameters and analyzed at approximately 10% of the sample load in <br /> order to establish method-specific control limits. The DCS <br /> results associated with your samples are on the attached Duplicate <br /> Control Sample Report. <br /> Accuracy is measured by Percent Recovery as in: <br /> recovery = tmeasured 'concentration] x 100 <br /> (actual concentration) <br /> Precision is measured using duplicate tests by Relative Percent Difference <br /> (RPD) as in: <br /> o o/ � <br /> RPD = (/ recovery test 1 - recovery test 2) <br /> x 100 <br /> (% recovery test .! + % recovery test 2)/2 <br />