- 2 - <br /> ■ Is regulated by the State Department of Health Services (DHS)l- <br /> and <br /> DHS);and <br /> ■ Is subject to the notification requirements for wells found to have <br /> contaminants in excess of maximum contaminant levels or action <br /> levels established by DHS. [Health & Saf. Code, § 25299.97, subd. <br /> (a)(1)] <br /> What is the deadline for performing ELD and how often does ELD have to be <br /> performed on a subiect UST system? <br /> For UST systems with a single-walled component, ELD must be performed no later <br /> than 18 months following receipt of notification from the State Water Board and be <br /> repeated every thirty-six (36) months thereafter [Cal. Code Regs., Title 23, § 2644.1, <br /> subd. (a) (3)]. <br /> • What is a single-walled component? A single-walled component is any part of <br /> a UST system that is constructed with walls made of only one thickness of <br /> material. Laminated, coated, or clad materials are all considered single-walled <br /> [Health & Saf. Code, § 25281, subd. (r)]. Tanks that were lined to meet the 1998 <br /> upgrade requirements are also considered to be single-walled. UST systems with <br /> any of the following components are considered "single-walled": a single-walled <br /> tank, single-walled pressurized piping, single-walled conventional suction piping, <br /> a dispenser without under-dispenser containment, or a turbine that is not <br /> contained in a sump. However, single-walled vent or tank riser piping, vapor <br /> recovery piping, and "safe" or "European" suction piping are not considered <br /> single-walled components of UST systems if they meet the definition of section <br /> 2636 (a)(1), (2), or (3) [Cal. Code Regs., Title 23, § 2640, subd. (e)(1)]. UST <br /> systems with a single-walled component were typically installed on or before <br /> January 1, 1984, although some may have been installed between January 1, <br /> 1984 and July 1, 1987, <br /> For UST systems with secondary containment that were installed before July 1, 2003 <br /> and are located within 1,000 feet of a public drinking water well, one-time ELD testing is <br /> required [Health & Saf. Code, §25292.5, subd. (a)]. <br /> • What is an UST system with secondary containment? An UST system with <br /> secondary containment has a second containment around all regulated single- <br /> walled components. An UST system with secondary containment at a minimum <br /> includes all of the following: a double-walled tank, double-walled piping (unless <br /> piping is "safe" or "European" suction), a turbine containment sump and under- <br /> dispenser containment. UST systems that meet the criteria of secondary <br /> containment were typically installed after July 1, 1987, althou6h some may have <br /> been installed between January 1, 1984 and July 1, 1987. <br /> In addition, Health and Safety Code, §25289, subdivision (b) authorizes the State Water <br /> Board to require ELD testing when the State Water Board finds that the burden of the <br /> testing, including costs, bears a reasonable relationship to the need for the testing and <br /> reporting. The State Water Board finds that the burden of imposing required ELD testing <br /> of USTs located within 1000 feet of a public drinking water well on owners or operators <br /> California Environmental Protection Agency <br /> Ca Recycled Paper <br />