Laserfiche WebLink
0 Heavy equipment including backhoe and trucks. W r <br /> 0 Unsupported excavations. <br /> 5.2 UNDERGROUND UTILITY HAZARDS <br /> Underground utilities shall be identified by the Client prior to initiating any subsurface <br /> LI investigation or work. <br /> 5.3 LOCATION OF UNDERGROUND UTILITIES <br /> USA Private Locator Plans Check X Property Owner <br /> L1 <br /> 5.4 OVERHEAD POWER LINES <br /> Whenever possible, avoid working under overhead high voltage lines. If overhead power fines <br /> are present on the site, the following are minimum clearances to be maintained between <br /> overhead high voltage lines and personnel and equipment: <br /> Nominal Voltage Minimum Required <br /> (phase to phase) Clearance (feet) <br /> t <br /> 750 - 50,000 10 <br /> 50,000 - 75,000 11 <br /> 75,000 - 125,000 13 <br /> 125,000 - 175,000 15 <br /> 175,000 - 250,000 17 <br /> 250,000 - 350,000 21' <br /> 370,000 - 550,000 27 <br /> 550,000 - 1,000,000 42 <br /> (Based on CCR Title 8, Section 2946.) <br /> E — 4 D.198117 H&SPL.AN.WPN <br /> BOYARAN & ROSS, INC. <br /> Environmental Scientists & Engineers <br />