Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ® Repair Inspection ® 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10422475 18/1 /2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As.) <br /> Yosemite Avenue Arco Am Pm <br /> Business Site Address City ZIP Code <br /> 1711 E . Yosemite Ave . Manteca 95336 <br /> II, UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the iCC Certification.) Phone # <br /> Guadalupe Sanchez 925 470 - 0803 Ext. <br /> Contractorfrank Tester License # iCC Certification # ICC Certification Expiration Date <br /> 10005444 5250451 4/5/2021 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method Used: ® Manufacturer Guidelines (Specify) OPW Overfill Valva in Tank Shut off Level Worksheet <br /> ❑ Industry Code or Engineering Standard (Specify) <br /> ❑ Engineered Method (Specify) <br /> Attach the Inspection procedures and all documentation required to determine the results. # of Attached Pages: 11 <br /> Tank ID: (By tank number, stored product, etc.) T1 : 87 M T2 : 87 S T3: 91 <br /> What is the tank inside diameter? (inches) 117 117 117 <br /> Is the fill piping secondarily contained? ® Yes ❑ No ® Yes ❑ No ® Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ❑ No <br /> OPW OPW OPW <br /> Overfill Prevention Equipment Manufacturer(s) <br /> What is the overfill prevention equipment ® Shuts Off Flow ® Shuts Off Flow ® Shuts Off Flow ❑ Shuts Off Flow <br /> response when activated? ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> (Check all that apply.) ❑ AN Alarm ❑ AN Alarm ❑ AN Alarm ❑ AN Alarm <br /> Are flow restrictors installed on vent piping? ❑ Yes ® No ❑ Yes ® No ❑ Yes 10 No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention 104 104 104 <br /> set to activate? (Inches from bottom of tank.) <br /> What is the percent capacity of the tank at which 94 94 94 <br /> the overfill prevention equipment activates? <br /> Is the overfill prevention in proper operating ® Yes ® Yes ® Yes ❑ Yes <br /> condition to respond when the substance ❑ No ❑ No ❑ No ❑ No <br /> reaches the appropriate level? (Specify in section V.) 11 (Specify in section V.) (Specify in section V.) (Specify in section V.) <br /> IV, SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention inspection Results ® Pass ❑ Fail ® Pass ❑ Fail ® Pass ❑ Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> All items marked °Fail" must be explained in this section. Any additional comments may also be provided here. <br /> All drop tubes were replaced <br /> ENVIRONMENTAL HEALTH <br /> DEPARTN4FNT <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations, title 23, division 3, <br /> chapter 16, section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> �-- Wisp ; <br /> N the facility has more components than this form acc mmodates, a dl nal copies of this page may be attached. <br /> r3:RC = r jd*v„is Fewinvvnar*al Rarvvfinn 14vatarn In = kfPn i 1mHnn 1 LCT = 11nAv vry mrl ctrvam tank irr = Infamafku*ad r`.rvia rdV inrli AN = Ai viit�la and vice a1 <br />