Laserfiche WebLink
i <br /> 01 March 2004 <br /> . AGE-NC Project No 99-0645 <br /> IPage 7 of 11 <br /> in concentrations of 0 040 mg/Kg and 0 030 rng/Kg, respectively <br /> Results from V W 1 A showed TPH-g and TAME at 40 feet at concentrations of 4 6 mg/Kg and <br />' 0 01 Omg/Kg,respectively MTBE was detected from 40 to 60 feet,ranging from 0 030 mg/Kg to 4 2 <br /> mg/Kg <br />' Soil from VW3 had MTBE at 30 and 40 feet with concentrations of 0 020 mg/Kg and 0 060 mg/Kg, <br /> respectively <br />' No other target analytes were detected in the samples analyzed Analytical results of the soil samples <br /> are summarized in Table 2 The laboratory report(CTEL Lab Project No CT214-0309068),quality <br /> assurance and quality control (QA/QC) and chain-of-custody are included in Appendix E <br /> I <br /> 33 ANALYTICAL RESULTS OF SVE SOIL VAPOR SAMPLES <br />' Analytical results of soil vapor samples were generally highest in the second sample collected on 18 <br /> • September Extraction well V W 1 B results indicated TPH-g was detected In all the soil vapor <br />' samples at concentrations ranging from 11,000 micrograms per liter(p g/L) to 14,000µg/L,benzene, <br /> toluene, ethylbenzene and xylenes were detected lin every sample at concentrations as high as 54 <br /> tig/L benzene, 1,400 µg/L toluene, 160 µg/L ethylbenzene, 990 µg/L xylenes, and MTBE was <br />' detected in all the samples ranging from 730 pg/L to 860 µg/L <br />' Toluene was detected in one sample collected from VW 1 A on 06 October at a concentration of <br /> 0 39 gg/L No other analytes were detected at or above laboratory reporting limits in the soil vapor <br /> samples Analytical results of the vapor samples are included in Table 3 The laboratory report(MAI <br />' Lab Project No 0309365 and 0310096),QA/QC and chain-of-custody are included in Appendix F <br />' 34 SVE PILOT TEST RESULTS <br /> On 18 September and 06 October 2003, the SVE unit was operated at approximately 2,00 RPMs for <br />' the eight hour tests <br /> The shallow test results indicated the flow rate was initially measured at 42 cfm(standard cubic feet <br />' per minute) and the maximum observed was 75 cfin OV readings ranged from 923 ppm to 1,100 <br /> ppm Induced vacuum measured at the extraction well VW 1B ranged from 20 to 32)inches of water <br /> On 06 October 2003, the lower screened vapor extraction test Indicted that the flow rate was <br />' measured between 25 cfm and 31 cfrn, a much lower flow was observed OV readings ranged from <br /> 1 2 ppm to 2 5 ppm, which was consist across the pilot test Induced vacuum measured at the <br /> i extraction well (VW 1 A) was always greater than 100 inches of water <br />' Advanced GeoEnviranmental,Inc <br />