My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1521
>
2200 - Hazardous Waste Program
>
PR0507077
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2020 8:39:40 AM
Creation date
5/13/2020 4:12:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0507077
PE
2229
FACILITY_ID
FA0005303
FACILITY_NAME
HOLT OF CALIFORNIA
STREET_NUMBER
1521
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337015
CURRENT_STATUS
01
SITE_LOCATION
1521 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
468
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
wood. <br /> Attachment 3. Hydrostatic Analysis in Attachment 3 indicates that the tank <br /> requires anchoring based on potential buoyancy. <br /> Seismic/Anchoring findings: The tank as designed and operated, and the <br /> containment area in which it is located are adequately anchored and mee <br /> minimum seismic safety standards. Initials: �e <br /> Leak Test 66265.192(k)(10): <br /> Brief description of leak test, including type of test used, and results of <br /> test: This tank was integrity tested based on the Steel Tank Institute's Standard <br /> SP001, "Standard for the Inspection of Aboveground Storage Tanks" (STI <br /> SP001) and recommendations from the manufacturer. This standard provides <br /> recommended integrity testing schedules based on risk to the environment, <br /> considering factors such as spill control, release detection methods, and storage <br /> capacity. Table 5.5, "Table of Inspection Schedules", of STI SP001 recommends <br /> tanks of this size and type undergo periodic visual, documented inspections to <br /> assess general AST conditions. These inspections may be conducted by the <br /> AST owner and without suspending AST operations or removing the AST from <br /> service. Holt of CA conducts these types of inspections on a daily basis. The tank <br /> inspector reviewed Holt of California inspection logs and conducted his own <br /> assessment based on the attached checklist. The tank was deemed to be in <br /> proper working order and the integrity sound. Sample inspection logs are located <br /> in Attachment 2. <br /> Integrity testing findings: Based on the above noted integrity test and the <br /> results obtained from that test, the tank has sufficient integrity for its in efo ded <br /> use. Initials: l"I �d <br /> Tank Drawing 66265.192(k)(2)(E): See manufacturer's drawing in Attachment 3 <br /> for dimensions of the tank. See also Attachment 1 Photolog for locations of <br /> piping, pumps, and other ancillary equipment. <br /> M- � <br /> >� �tspr,kr <br /> D t" <br /> t 'CYyJMVt+3 CJs <br /> 0,T, . <br /> Facing <br /> N E S W (plan view, N is to the left) <br /> See also Attachment 3, for a manufacturer's diagram with dimensions. <br /> Wood Environment & Infrastructure Solutions, Inc. 275 Gal. Waste Antifreeze Tank <br />
The URL can be used to link to this page