Laserfiche WebLink
REVISIONS <br /> 90' _ TABLE i DESCRIPTION DATE BY <br /> CLIP SfZE ROPE IHIHimm 4 CLIPS ROD. PYOLNT OF ROPE *TQ4QIE IN <br /> (ItC SI (I lUdl-BRCK t7NCIES) Ft.Lbs CODES: <br /> —i- vn 1/4 z 4-v4 Is CBC 2010 <br /> ' 1 POSTS TANDS BASE PLATES NT'BE INSTALLED TiE T ITT NG TORp,E VALUES SHOWN ARE BASED LPON THE THREADS BEING CLEAN,CRY.AND <br /> 0.4 FLAT SIBS OF THE C MAIMfrhT TANX. FREE LICATI6N.l IBC 2009 <br /> ASCE 7.05 <br /> AISC 13TH EDITION <br /> r' �E SEISMIC DESIGN: <br /> a ;• ' I Zip Code=92799, Site class 0-Fo=L0, Fv=1.5, <br /> 180* - 1 Q' Ss= 1.598, SI =0,5604, I= 1,5, R=3.0 <br /> — <br /> 1 ' U®_ .35.IW=0.480 W i <br /> I� WIND DESIGN; <br /> IBC/CBC- 150 MPH <br /> CABLE CLIPS MINIMIMI 2 REQ'D. Oz =0.00255KzKxtKdVA2I=5149 PSF <br /> y FOR EACH CABLE TURN-BACK (Kz=0,85, Kzt= 1.0, Kd= 0.95, I = 1.15) <br /> - - (TABLE 1) GENERAL: <br /> 1, ALL CONSTRUCTION SHALL MEET LOCAL BUILDING CODE <br /> REQUIREMENTS AND BE APPROVED BY THE BUILDING <br /> 270' OFFICIAL. <br /> 2, THESE GUIDELINES HAVE BEEN PROVIDED TO SPECIFY THE <br /> RESTRAINT RECOMMENDATIONS FOR SNYDER INDUSTRIES <br /> BULK STORAGE TANKS, <br /> CONCRETE: <br /> 1, CONCRETE SHALL HAVE A MINIMUM DESIGN AS PER <br /> DRAWING REFERENCED IN SPECIFICATION CHART BELOW, <br /> [2)2" SQ. I/4° THK. WASHERS 2. CONCRETE PAD DESIGN SHOULD BE REVIEWED AND APPROVED BY <br /> THE BUILDING OFFICIAL BASED ON SPECIFIC APPLICATION AS i <br /> OTHER DESIGN PARAMETERS ARE POSSIBLE DEPENDING UPON SITE <br /> if CONDITIONS. <br /> u STRUCTURAL STEEL: <br /> 1. ALL STRUCTURAL STEEL COMPONENTS SHALL BE NEW AND OF <br /> GABLE ATTACHMENT DETAIL BASIC OPEN HEARTH PROCESS STEEL CONFORMING TO ALL <br /> APPLICABLE REQUIREMENTS OF ASTM A36(STRUCTURAL STEEL <br /> FOR BRIDGES AND BUILDINGS-Fy=36,000 PSI.). <br /> J'PE'l'p'l <br /> IP(2 EA. REQ'D) 2, ALL ARC WELDING ELECTRODES SHALL CONFORM TO ASTM A233 FDR <br /> STEEL ARE WELDING ELECTRDDES, ELECTRODES SHALL BE AS <br /> WG. A-5919 OR A-4898. RECOMENOEO BY THE MANUFACTURES FOR THE POSITIONS AND <br /> OTHER CONDITIONS 01:ACTUAL USE, WELDING SHALL CONFORM <br /> tSt4EA '2I TO REQUIREMENTS OF AMERICAN WELDING SOCIETY AWS 0121. <br /> 3, ALL SHARP EDGES AND CORNERS SHALL BE REMOVED ON ALL <br /> l CLIP(2 EA. REQ'D) STRUCTURAL STEEL COMPONENTS. <br /> ER DWD. A-4869 4. CABLES TO BE 7XI9 STRANDED CORE CONSTUCTION SIZED PER CHART. <br /> MATERIAL TO BE SPECIFIED BY CUSTOMER ORDER(MINIMUM <br /> SEE DETAIL FOR CABLE ATTACHMENT BREAKING STRENGTH EQUAL TO OR GREATER THAN 304 SS RATING). <br /> 5. ANCHOR BOLTS TO BE HILTI ADHESIVE ANCHORS, MODEL <br /> HIT-RE 500-SO WITH SIZE, MATERIAL, ANO EMBEDMENT AS <br /> SPECIFIED PER SPECIFICATION CHART BELOW. SPECIAL <br /> INSPECTION IS REQUIRED. <br /> ALL OTHER FASTENER MATERIALS MUST CORRESPOND TO THE . <br /> TYPE OF ANCHOR SELECTED. <br /> TABLE 2 i <br /> TANK DAL. TANK DIA. TANK HT. ANCHOR BOLT QTY. EMBEDMENT CABLE 0 CABLE HT. Pi CLIP Sl CLIP FOUNDATION SN YDER INDUSTRIES INC , <br /> 35 22' 36" 3/4° HILTI HIT-RE 500-SD 4 6"T 1/4" 24" A-5919 A-4869 B-5921 LINCOLN, NE 68504 PHONE: (402)467-5227 FAX: (402)465-1210 <br /> 60 26° 41" 3/4" HILTI HIT-RE 500-SO 4 6°T 1/4" 24" A-5919 A-4869 B-5921 SCALE: NTS APPROVED BY: DRAWN BY: NLE <br /> 120 34° 49" 3/4" HILTI HIT-RE 500-SO 4 6°T 1/4° 24° A-5919 A-4869 B-5921 DATE: 01/05/2010 REVISED: <br /> 150 34^ 60" 3/4" HILTI HIT-RE 500-SO 4 6`T 1/4" 42" A-4898 A-4869 B-5921 S,I,I, TANK SEISMIC RESTRAINT SYSTEM RECOMENOATIONS <br /> _.;;";-275 47° 60" 3/4" HILTI HIT-RE 500-SO4 6°Tv 1/4° 42° A-4898 A-4869 B-5921 FOR S.I.I. 35 - 500 GALLON QUAL CONTAINMENT TANK (DCT) SYSTEMS <br /> 360 53` 60" 3/4" HILT[ HIT-RE 500-SO 4 61Tv 1/4" 1 42° A-4898 A-4869 B-5921 TOLERANCES UNLESS SPECIFIED OTHERWISE DRAWING NUMBER <br /> ANGULAR: t 1° B-5920A <br /> 500 53° 79" 3/4" HILT[ HIT-RE 500-SD 4 6-T ]/4° 42° A-4£198 A-4869 B-5921 DECIMAL: .XXX=t 1/32° <br />