My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1521
>
2200 - Hazardous Waste Program
>
PR0507077
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2020 8:39:40 AM
Creation date
5/13/2020 4:12:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0507077
PE
2229
FACILITY_ID
FA0005303
FACILITY_NAME
HOLT OF CALIFORNIA
STREET_NUMBER
1521
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337015
CURRENT_STATUS
01
SITE_LOCATION
1521 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
468
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
wood. <br /> Secondary Containment Assessment <br /> Tank Name/marking: Tank No. 14, 1,000 Gal. <br /> ConVault Waste Oil Tank <br /> The secondary containment calculations provided for on this page are for secondary <br /> containment systems that utilize a double-walled tank for containment. <br /> ConVault tank is double-walled. No additional secondary containment is required. <br /> Design of tank 66265.193(e)(3): <br /> The primary tank is welded 10-gauge steel encased in geomembrane and concrete and <br /> rests on concrete support legs. The primary tank exterior is insulated with a minimum of <br /> % inch thick Styrofoam covered (wrapped) by a 30-mil high density polyethylene <br /> geomembrane which provides secondary containment. The tank includes an integrated <br /> leak detection tube that allows monitoring for leaks from the primary tank into the <br /> secondary containment. The leak detection chamber is checked as part of routine <br /> monitoring and maintenance. <br /> The geomembrane is covered by 6 inches of concrete reinforced with Y2-inch rebar to <br /> provide fire protection and ballistic and vehicle impact protection. <br /> The 30-mil high density polyethylene membrane also prevents external corrosion to the <br /> primary tank. The piping between the sump table and pump is equipped with a <br /> filter/cleanout to protect the pump. Water that may accumulate in the primary tank via <br /> condensation is removed with the oil when the tank contents are collected for recycling <br /> approximately every week. The frequent recycling process minimizes internal tank <br /> corrosion. <br /> Visual observation of containment area 66265.66265.193(f): <br /> Provide a brief description of the condition of the tank. The tank system has spill control. <br /> The tank is filled using attached/dedicated piping from the sump table. The piping is <br /> visually inspected for leaks on a daily basis; the piping system is only pressurized during <br /> operation. The tank is fitted with a level gauge that is monitored visually to prevent <br /> overfilling. The tank and sump table system are maintained within an area surrounded <br /> by a 4-inch-high concrete curb and covered by a canopy. There are no drains within the <br /> curbed area and the tank system is not exposed to precipitation. The secondary <br /> containment system meets the requirements described in 22 CCR §66265.193. <br /> Secondary Containment findings: The secondary containment system is of sufficient <br /> capacity and condition for the containment of releases from all tanks and ancillary <br /> equipment. Initials: _ <br /> 6,112, <br /> Wood Environment & Infrastructure Solutions, Inc. 1,000 Gal. Waste Oil Tank <br />
The URL can be used to link to this page
Your browser does not support the video tag.