wood. <br /> inhibitors are present in the resin. The material handled in the operation of <br /> the waste antifreeze tank, i.e., waste antifreeze, is generally non-corrosive <br /> to rubber hoses and plastics. <br /> Structural support: The subject antifreeze tank is co-located adjacent to <br /> a 1,000-gallon waste oil tank. This tank is anchored to a concrete pad' <br /> (reportedly 8 to 10 inches thick) and bounded by an integrated curb, both <br /> in place since the placement of the tank back in 2012. The Accumulation <br /> Area was constructed in the early 1990's according to Holt. The weight of <br /> a full tank is distributed over the entire tank base. Based upon the <br /> construction information provided by Holt to Wood, the concrete <br /> foundation is sufficient to support the weight of a full tank. <br /> This tank is restrained by means of seismic anchors interconnected to <br /> braided steel wire rope that wraps around and over the top of the tank. <br /> Details of the seismic restraint system are provided elsewhere in this <br /> document. <br /> Double wall tank construction encloses and interlocks the outer and inner <br /> tank to prevent rain and debris from entering the outer containment. The <br /> outer containment tank bottom has integral 4-inch-high forklift channels <br /> made of the HDLPE resin. The outer containment tank rests on a concrete <br /> slab which is surrounded by a concrete curb, situated under a canopy, and <br /> protected from vehicles by steel bollards at the location indicated on <br /> Attachment 1, Figure 2. <br /> The Frost Line Depth is 0, Air Freezing Index is 0 — 1000, and the Mean <br /> Annual Temperature is 55 degrees Fahrenheit; all are from the California <br /> Residential Code specific to San Joaquin County.2 Thus, 0 inches below <br /> undisturbed soil would be the requirement to avoid frost heave. Frost <br /> heave is not an issue at the site requiring mitigation. <br /> No part of the tank system (i.e., external metal component) is or will be in <br /> contact with soil or water (66265.192(a)(3)); thus, no external corrosion <br /> protection is needed to ensure the integrity of the system. <br /> Other identifying features: The tank top has a threaded, 14-inch <br /> diameter, black, plastic lid (manway) with an inner 5-inch vented cap. <br /> Per email from Mike Mason of Holt of California to Greg Meyer that occurred on May 1, 2020, <br /> the best information available regarding the construction of the concrete pad is that the concrete <br /> is between 8 inches and 10 inches in thickness. <br /> 2 http://www.slaov.org/commdev/cqi- <br /> bin/cdyn.exe/file/Building%2FBuilding%2FCLIMATIC%20AND%20GEOGRAPHIC%20DESIGN% <br /> 20CRITERIA.pdf <br /> Wood Environment & Infrastructure Solutions, Inc. 275 Gal. Waste Antifreeze Tank <br />