Laserfiche WebLink
1825 Yosemite Blvd. <br /> Modesto, CA 95354-2998 <br /> 209.629.4110 <br /> _ <br /> LIC. #479018 <br /> February 14 , 1992 <br /> Murrey Ivy <br /> Simpson Paper <br /> RE : Abandonment of Wells No . 1 & 3 <br /> Murrey : <br /> Pursuant to your telephone conversation with Tom Weimer on <br /> December 12 , 1991 , follows is our planned abandonment method <br /> and estimated cost for each well . <br /> 1 . Pull existing DWT pump . <br /> 2 . Perforate casing from bottom to top . <br /> 3 . Install 2" tremie pipe to bottom of well . <br /> 4 . Delta Pumping to pump the grout . <br /> 5 . Pump in approximately 10 C .Y . of nine,- sack sand and <br /> cement grout ( 1 .4 cubic feet per foot ) . <br /> 6 . Withdraw tremie pipe as grout rises in well . <br /> 7 . At the owner ' s option , we would cut casing off six feet <br /> below grade and cap with cement , otherwise we would bring <br /> grout to surface of concrete well head . <br /> Estimated cost each : $ 7 , 800 . 00 <br /> Respectfully , <br /> HOWK SYSTEMS <br /> ary Rossiter <br /> Sales Engineer <br /> 7 <br /> Formerly Howk Well & Equipment Co., Inc. <br />