My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
STOCKTON
>
942
>
2900 - Site Mitigation Program
>
PR0516727
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2020 3:51:49 PM
Creation date
5/14/2020 1:44:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0516727
PE
2965
FACILITY_ID
FA0012758
FACILITY_NAME
DIAMOND FOOD PROCESSORS OF RIPON
STREET_NUMBER
942
Direction
S
STREET_NAME
STOCKTON
STREET_TYPE
AVE
City
RIPON
Zip
95366
APN
25934012
CURRENT_STATUS
01
SITE_LOCATION
942 S STOCKTON AVE
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
505
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING PROGRAM -3- <br /> SIMPSON PAPER COMPANY, RIPON MILL <br /> SAN JOAQUIN COUNTY <br /> In conducting the receiving water sampling, a log should be kept of the receiving <br /> water conditions throughout the reach bounded by Stations R-1 and R-2. Attention <br /> should be given to the presence or absence of: <br /> a. Floating or suspended matter <br /> b. Discoloration <br /> c. Bottom deposits <br /> d. Aquatic life <br /> Notes on receiving water conditions shall be summarized in 'the monitoring report. <br /> WATER SUPPLY MONITORING <br /> A sampling station shall be established where a representative sample of the <br /> water supply can be obtained. The following shall constitute the water supply <br /> monitoring program: <br /> Constituents Units Sampling Frequency <br /> Standard Minerals mg/1 Yearly at same time <br /> as effluent samples <br /> Total Dissolved Solids mg/l Monthly at same time <br /> as effluent sample, <br /> otherwise yearly <br /> REPORTING <br /> In reporting the monitoring data, the Discharger shall arrange the data in tabular <br /> form so that the date, the constituents, and the concentrations are readily <br /> discernible. The data shall be summarized in such a manner to illustrate clearly <br /> the compliance with waste discharge requirements. <br /> Monthly monitoring reports shall be submitted to the Regional Board by the 15th <br /> day of the following month . <br /> The results of any monitoring done more frequently than required at the locations <br /> specified in the Monitoring and Reporting Program shall be reported to the Board. <br /> Upon written request of the Board, the Discharger shall submit a report to the <br /> Board by 30 January of each year. The report shall contain both tabular and <br /> graphical summaries of the monitoring data obtained during the previous year. In <br /> addition, the Discharger shall discuss the compliance record and the corrective <br /> actions taken or planned which may be needed to bring the discharge into full <br /> compliance with the waste discharge requirements. <br />
The URL can be used to link to this page
Your browser does not support the video tag.