My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BLACK DIAMOND
>
927
>
2200 - Hazardous Waste Program
>
PR0513924
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2020 1:37:43 PM
Creation date
5/15/2020 10:39:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0513924
PE
2227
FACILITY_ID
FA0003775
FACILITY_NAME
TIGER LINES INC
STREET_NUMBER
927
Direction
E
STREET_NAME
BLACK DIAMOND
STREET_TYPE
WAY
City
LODI
Zip
95240
APN
04903033
CURRENT_STATUS
01
SITE_LOCATION
927 E BLACK DIAMOND WAY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Anchor Designer TM Company: Mike Smith Engineering,Inc. Date: 2/1412014 <br /> Engineer: Mike Smith Page: 1/3 <br /> Software Project: Tiger Lines <br /> Version 2.4.5673.0 Address: P,O.Box 611,Lodi,CA 95241 <br /> Phone: 209-334-2332 <br /> E-mail: mlke@mseng.corncasibiz.net <br /> 1.Pratnct Inforrysatlpn <br /> Customer company: Project description:Waste 011 Tank Anchorage <br /> Customer contact name. Location:4 Locations <br /> Customer e-mail: Fastening description:Post installed anchors <br /> Commenl: <br /> 2.lnpkd a&AnclOrP gm <br /> General Base Material <br /> Design method:ACI 318-11 Concrete;Normal-weight <br /> Units:Imperial units Concrete thickness,h(inch):6.00 <br /> Slate:Cracked <br /> Anchor Information: Compressive strength,fe(psi):2500 <br /> Anchor type:Torque controlled expansion anchor 4J.,v:1.0 <br /> Material:Carbon Steel Reinforcement condition:B tension,B shear <br /> Diameter(inch);0.625 Supplemental reinforcement:Not applicable <br /> Nominal Embedment depth(inch);3.375 Reinforcement provided at comers:No <br /> Effective Embedment depth,her(Inch):2.750 Do not evaluate concrete breakout in tension:No <br /> Code report:ICC-ES ESR-3037 Do not evaluate concrete breakout in shear:No <br /> Anchor category:1 Ignore Edo requirement:Not applicable <br /> Anchor ductility:Yes Build-up grout pad:No <br /> hm.(inch):5.50 <br /> Ge(inch);7.50 Base Plate <br /> Cm„(inch):6.50 Length x Width x Thickness(inch):6.00 x 6,00 x 0.50 <br /> S,m(inch):5.00 <br /> Load and Geometry <br /> Load factor source;ACI 318 Section 9.2 <br /> Load combination:U=0.91)+1.0E Z <br /> Seismic design:Yes <br /> Anchors subjected to sustained tension:Not applicable <br /> Ductility section for tension:D.3.3.4.3(c)is satisfied <br /> Ductility section for shear:D.3.3.5.3(c)is satisfied <br /> Do factor:not set u la <br /> Apply entire shear load at front row:No <br /> Anchors only resisting wind and/or seismic loads:No <br /> <Figure 1> <br /> n- <br /> Y <br /> 0 tt•16 <br /> xaan <br /> X <br /> 0 <br /> �d <br /> _ _. _4 <br /> Input data and results must he checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. <br /> Simpson Strong-Tie Company Inc, 5955 W,Les Posilas Boulevard Pleasanton,GA 94588 Phone:925.560,9000 Fax:925.847.3871 www.strongtie.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.