My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4987
>
2200 - Hazardous Waste Program
>
PR0513935
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/3/2020 8:59:55 AM
Creation date
5/15/2020 11:41:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0513935
PE
2227
FACILITY_ID
FA0003969
FACILITY_NAME
PEP BOYS #711
STREET_NUMBER
4987
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10416027
CURRENT_STATUS
01
SITE_LOCATION
4987 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pep Boys#711 <br /> ASSESSMENT,continued <br /> 7. Stray electric current <br /> 8. Existing corrosion-protection measures <br /> And <br /> B)Type and degree of external corrosion that are needed consisting of one or more of the <br /> following: <br /> 1. Corrosion-resistant materials (i.e.fiberglass) <br /> 2. Corrosion-resistant coating with cathodic protection <br /> 3. Electrical isolation devices <br /> This section not applicable. The tank is above ground and inside a structure. It is not in contact <br /> with soil or water. <br /> (a)(4) -- Not Applicable if this is an above ground tank system. The subject tank is an above <br /> ground tank. <br /> (a)(5) --Design considerations to ensure that: <br /> A) Tank foundations will maintain the load of a full tank.See calculations in <br /> Appendix B. <br /> B)Tank systems will be anchored to prevent floatation or dislodgement where the tank system <br /> is placed in a saturated zone, or is located within a seismic fault zone. The tank is not in a <br /> saturated zone.See seismic calculations in Appendix B. <br /> C)Tank systems will withstand the effects of frost heave. <br /> Title 22, 66265.192(b) (1-6)Not applicable. The tank is at a low elevation in California in an <br /> area not subject to frost heave. <br /> --Independent, qualified professional engineer's inspection for the presence of the following <br /> after installation; <br /> 1) Weld breaks.See Table IV. <br /> 2) Punctures.See Table IV. <br /> 3) Cracks.See Table IV. <br /> 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.