My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4987
>
2200 - Hazardous Waste Program
>
PR0513935
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/3/2020 8:59:55 AM
Creation date
5/15/2020 11:41:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0513935
PE
2227
FACILITY_ID
FA0003969
FACILITY_NAME
PEP BOYS #711
STREET_NUMBER
4987
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10416027
CURRENT_STATUS
01
SITE_LOCATION
4987 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN xdDAQI <br />C0L.IJT <br />Environmental Health Department <br />AMENDED <br />1/21/2020 <br />Large Quantity Hazardous Waste Generator Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />PEP BOYS #711 <br />4987 WEST LN, STOCKTON <br />January 13, 2020 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />during the use of the tank system or component, consisting of one or more of the following: <br />1. corrosion -resistant materials of construction such as special alloys or fiberglass -reinforced plastic; <br />2. corrosion -resistant coating (such as epoxy or fiberglass) with cathodic protection (e.g., impressed current or <br />sacrificial anodes); and <br />3. electrical isolation devices such as insulating joints and flanges; <br />(4) for underground tank system components that are likely to be affected by vehicular traffic, a determination of <br />design or operational measures that will protect the tank system against potential damage; and <br />(5) design considerations to ensure that: <br />(A) tank foundations will maintain the load of a full tank; <br />(B) tank systems will be anchored to prevent flotation or dislodgement where the tank system is placed in a <br />saturated zone, or is located within a seismic fault zone; and <br />(C) tank systems will withstand the effects of frost heave. <br />Title 22 California Code of Regulations section 66270.11 <br />(d) Certification. I certify under penalty of law that this document and all attachments were prepared under my <br />direction or supervision in accordance with a system designed to assure that qualified personnel properly gather <br />and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or <br />those persons directly responsible for gathering the information, the information submitted is, to be the best of my <br />knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting <br />false information, including the possibility of fine and imprisonment for knowing violations. <br />Title 22 California Code of Regulations section 66265.192(k) <br />The tank system assessment shall include all of the following information: <br />(1) tank configuration (i.e., horizontal, vertical), material of construction, and gross capacity (in gallons); <br />(2) design standard(s), if available, according to which the tank and ancillary equipment were or will be constructed <br />and all of the following information: <br />(A) material of construction; <br />(B) material thickness and the method used to determine the thickness; <br />(C) description of tank system piping (material, diameter); <br />(D) description of any internal and external pumps; and <br />(E) sketch or drawing of tank including dimensions. <br />(3) documented age of the tank system (if tank was previously used), if available, (otherwise, an estimate of the <br />age); <br />(4) description and evaluation of any leak detection equipment; <br />(5) description and evaluation of any corrosion protection equipment, devices, or material; <br />(6) description and evaluation of any spill prevention or overfill equipment; <br />(7) description and evaluation of secondary containment for the tank system (secondary containment must meet <br />minimum standards as specified in subsections 0)(1) through 0)(3) of this section) including applicable secondary <br />containment for ancillary equipment as required in subsection 66265.193(f); <br />(8) hazardous characteristics of the waste(s) that have been or will be handled; <br />(9) prior to placing a new tank system or component in use, an independent, qualified installation inspector or an <br />independent, qualified, professional engineer, registered in California, either of whom is trained and experienced in <br />the proper installation of tank systems, shall inspect the system or component for the presence of any of the <br />following items and document in writing the results of the inspection: <br />(A) weld cracks or breaks; <br />FA0003969 PR0513935 SCO01 01/13/2020 <br />EHD 22-02 Rev. 9/20/2019 Page 13 of 19 Large Quantity Hazardous Waste Generator OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.