My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BUCKLEY COVE
>
4950
>
2300 - Underground Storage Tank Program
>
PR0231028
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/27/2022 9:58:36 AM
Creation date
5/15/2020 2:32:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231028
PE
2361
FACILITY_ID
FA0003811
FACILITY_NAME
RIVER POINT LANDING MARINA-RESORT*
STREET_NUMBER
4950
STREET_NAME
BUCKLEY COVE
STREET_TYPE
WAY
City
STOCKTON
Zip
95219
APN
11820001
CURRENT_STATUS
01
SITE_LOCATION
4950 BUCKLEY COVE WAY
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� t Department Enwronmenta � Clealth <br /> SAN J O A Q U I N lot <br /> OUNTY Uj 1 , <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address: TDaRIVER POINT LANDING MARINA- RESORT' 4950 BUCKLEY COVE WAY , STOCKTON ary 28 , 2020 <br /> UST System Observations <br /> 314 HSC 25290. 1 , 25290 .2 , Failed to have secondary containment or secondary containment not tight ❑ V ❑ R ❑ COS <br /> 25291 <br /> 315 HSC 25291 (e) Water in secondary containment not removed , analyzed , and properly disposed of (pre,lul 2003) ❑ V ❑ R ❑ COS <br /> 316 HSC 25290 . 1 (c3), Secondary containment not constructed to prevent water intrusion (after Jul 2003) ❑ V ❑ R ❑ COS <br /> 25290 .2(c3) <br /> 317 CCR 2636, 2643(c)(1 ) 9 Line leak detector (LLD ) not installed ❑ V ❑ R ❑ COS <br /> 2666(f) <br /> 318 CCR 2666 (c), 2643(c) Leak detector failed to detect a 3 .0 gallons per hour leak at 10 pounds per square inch ❑ V ❑ R ❑ COS <br /> (1 ) <br /> 319 CCR 2635, 2637. 1 , No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested ❑ V ❑ R ❑ COS <br /> 2665, 2712 <br /> 320 CCR 2635, 2637.21 Failure to comply with the installation , inspection , or record keeping of the overfill prevention ❑ V ❑ R ❑ COS <br /> 2665, 2712 <br /> 321 CCR 2635(c)(1 ) Overfill prevention was overridden ❑ V ❑ R ❑ COS <br /> 322 HSC 25281 .6(a) Unburied below grade emergency generator system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 324 CCR 2717 . 1 (g) Tampered with red tag ❑ V ❑ R ❑ COS <br /> 325 CCR 2717 . 1 (f), Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST ❑ V ❑ R ❑ COS <br /> 125292 .3(c) <br /> 326 HSC 25299 (a)(9) Tampered with or disabled leak detection devices or alarms ❑ V ❑ R ❑ COS <br /> 327 CCR 2631 . 1 , 2660 (m) UST system not compatible with the substance stored ❑ V ❑ R ❑ COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑ V ❑ R ❑ COS <br /> 329 HSC 25298; CCR 2670 , Failed to comply with all permanent closure requirements ❑ V ❑ R ❑ COS <br /> 2672 <br /> 330 CCR 2636(f), 2666(c) , No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm ❑ V ❑ R ❑ COS <br /> 2666(f) <br /> 331 CCR 2630(d), 2641 (a) Liquid does not flow into the sump in the event of a leak (i .e. , failure to remove test boot). ❑ V ❑ R ❑ COS <br /> 332 CCR 2631 (b&d), Primary and/or secondary containment not constructed in accordance with the established standards ❑ V ❑ R ❑ COS <br /> 2666(b&e) <br /> 333 CCR 26352 2636(b), Failure to comply with the cathodic protection system requirements ❑ V ❑ R ❑ COS <br /> 2662, 2712 <br /> 334 CCR 2666(b)(2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair ❑ V ❑ R ❑ COS <br /> 335 CCR 2630 , 26329 2643 , Equipment or methods used to monitor the UST system are not certified by an independent third-party ❑ V ❑ R ❑ COS <br /> 2644. 1 <br /> 336 HSC 25292 .3(c)(1 )(C) Owner/operator allowed dispensing from a UST that has a red tag affixed to the fill pipe ❑ V ❑ R ❑ COS <br /> Single -Walled Non -Pressurized Piping <br /> 401 CCR 2636(a)(3 ), Suction piping not properly sloped or incorrectly located check valve ❑ V o R ❑ COS <br /> 2641 (b) <br /> 402 CCR 2643(d) Failure to conduct monitoring / maintain records for single-walled conventional suction (pre-1984) ❑ V ❑ R ❑ COS <br /> 403 CCR 2643(d), 2661 (f) Failure to conduct 0 . 1 gph test for single-walled conventional suction systems (pre-Jan 1984) ❑ V ❑ R ❑ COS <br /> 404 CCR 2643 (e) , 2661 (f) 0 . 1 -gph line test for single-walled gravity piping not performed biennialy or post repair (pre-1984) ❑ V ❑ R ❑ COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑ V ❑ R ❑ COS <br /> FA0003811 PR0231028 SC333 01 /28/2020 <br /> EHD 23-01 Rev, 9/20/2019 Page 3 of 4 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468-3420 1 F 209 464-0138 1 www .sjcehd .com <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.