Laserfiche WebLink
SAN JOAQUIN <br />CCUNT <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />CHARTER WAY PETRO INC. <br />508 W DR MARTIN LUTHER KING JR BLVD, <br />October 07, 2020 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />209 <br />CCR 2716(a -e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br />OBSERVATION: The designated operator failed to check and note all required items on the visual inspection <br />reports. The incorrect and missing information included the following from the inspection reports: <br />-In section 5 of the DO report of 12/06/2019 and 01/04/2020 the owner/operator failed to provide explanation of <br />follow-up action that will be taken for the statements provided by the DO in Section 3 <br />REGULATION GUIDANCE: During the visual inspection, the designated operator shall check that all required <br />testing and maintenance for the UST system have been completed and shall check all required items on the report. <br />CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br />all of the required information on the reports. <br />This is a repeat violation, Class II. <br />313 <br />HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product -tight. <br />OBSERVATION: Seepage was detected below the shear valve in the under dispenser containment (UDC) 1/2, <br />indicating a leak in the primary piping. <br />REGULATION GUIDANCE: All primary containment for the UST system must be product tight. <br />CORRECTIVE ACTION: Immediately have a properly licensed, trained, and certified contractor repair or replace the <br />failed component(s), under permit and inspection of the EHD if necessary. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by November 7, 2020 . <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br />of having them sign. Starting September 1, 2018, all in -office CERS help will be provided at EHD hourly rate <br />($152). To schedule an appointment, please call (209) 468-3420. <br />Documents provided during inspection: Inspection Report, Corrective Action Statement form & List of scheduled <br />free CUPA training classes <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received by: Date: October 07, 2020 <br />Inspector: <br />Inspector Phone: <br />Printed Name and Title: <br />VICKY VANG-LEE, EHS Trainee <br />() - <br />Ravinder Singh, Owner <br />FA0003720 PR0231057 SCO01 10/07/2020 <br />EHD 23-01 Rev. 9/20/2019 Page 4 of 4 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />