Laserfiche WebLink
. WORK REQUEST FORM <br /> Date of Request 021405 Requested Completion Date 021605 <br /> Proj Name Greer Construction Prod No 54 25291 0001 <br /> Site Address 15634 Steinegul Rd , Escalon Task 01 <br /> Project Manager Jeanne Homsey Field Tech Alex F / Charlie S <br /> Client Contact Brian Greer Phone No 838-3596 <br /> Regulatory Contact. Jeff Wong Phone No 468-0335 <br /> Approval Completion Date 0 <br /> Notify Client contact and Regulator 48 hrs prior to field work <br /> On-site contact Albert Veldstra 838-7894 <br /> Monitor DTW/DTB in all nine gw monitoring wells and on-site drinking water <br /> • well, if possible <br /> Purge and sample all wells MW-1-9 in order <br /> Monitoring order MW8, DW, 3,-4,9, 5, 6, 2 & 1 <br /> Monitor for D O with YSI 95 in all groundwater monitoring wells <br /> Contain well purged water Take two drums _ <br /> Sam le all wells for BTEX/TPHg and fuel ox enates by EPA 8260B <br /> Samples to Argon Labs Note in C-O-C to report MTBE at lowest detection Limit <br /> possible and to submit e-data in Geotracker format Global ID # T0607700051 <br /> All wells are two-inch dtw last 11104 —73-79' dtb —90-100' <br /> Prepare purchase order requisition form <br /> Note MW7 was converted to VE3 screen 40-50' well is dry <br /> AFLORE5IGREER doc <br />