Laserfiche WebLink
r <br /> a <br /> f f <br /> Fisco Warehouse; Site Background Information <br /> Page 4 of 5 <br /> Ground water samples CPT1-92-96 and CPT2-92-96 were collected from HU2; sample <br /> CPT3-92-96 was collected at the boundary between HU2 and HU3.TPH-g and TPH-d were <br /> detected in sample CPTI-92-96 at concentrations of 530 µg/1 and 98 µg/1, respectively. <br /> Toluene, ethylbenzene and total xylenes were detected in sample CPT1-92-96 at <br /> concentrations of 9.9 µg/I, 20 µg/i and 140 µg/l,respectively.No other target analytes were <br /> detected in the samples from HU2. <br /> Benzene and fuel additives were not detected at or above laboratory reporting limits in any <br /> of the ground water samples. <br /> The general count of heterotrophic organisms in soil sample CPTI-31 was 12.2 X 105 <br /> (colony-forming units/gram) cfu/g and the selective count was 2.1 X 105 cfu/g, which <br /> indicate a moderate population of organisms capable of gasoline metabolism. However,the <br /> nutrient concentrations are at moderate to high levels to sustain ongoing bioremediation; <br /> nitrates (NO3), phosphate (POO and ammonium (NH4) were detected in the sample at <br /> concentrations of 57.2 parts per million (ppm), 22 ppm and 28.38 ppm, respectively, <br /> indicating. The moisture content(MC) of the soil sample was 23%. <br /> On 14 January 2002, an 8-hour SVE pilot test was conducted at the site using vapor well VW-2, <br /> screened from 15 feet below surface grade(bsg)to 35 feet bsg as the extraction well. The pilot test <br /> was performed to provide SVE data prior to installation of a full scale remediation system <br /> TPH-g was detected in the soil gas/vapor samples(vapor samples)at concentrations ranging <br /> from 1,300 µg/l to 2,700 µg/1. Toluene, ethylbenzene and total xylenes were detected in the <br /> gas/vapor samples at concentrations as high as 47µg/1 toluene,30µg/1 ethylbenzene and 220 <br /> µg11 total xylenes. Benzene and MTBE were not detected at or above laboratory reporting <br /> limits in the gas/vapor samples. <br /> The SVE unit was operated at approximately 2,300 RPMs for the eight-hour test. The flow <br /> rate was measured between 25 cfin (standard cubic feet per minute) and 30 scfin for the <br /> eight-hour test. OV readings ranged from 108 to 363 ppm.Induced vacuum measured at the <br /> extraction well (VW-2)ranged from 54 to 72 inches of water. <br /> As expected, the greatest vacuum was measured in the observation point nearest the <br /> extraction well(VW-1),The lowest vacuum was measured in MW-6,approximately 66 feet <br /> north of the extraction point. The maximum vacuum measured at the observation points <br /> during the pilot test was plotted versus the distance from the extraction well. The effective <br /> radius of influence was determined by drawing a best-fit line though these data points to <br /> correlate distance to vacuum data.At a vacuum potential of 0.10 inches of water,the radius <br /> of influence is approximately 47 feet;at an induced vacuum potential of 1.0 inches of water, <br /> the radius of influence is approximately 30 feet; at 10.0 inches of water the radius of <br /> influence is approximately 13 feet. Based on the United States Environmental Protection <br /> Advanced GeoEnvirnnmental,Inc <br />