My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2900 - Site Mitigation Program
>
PR0545782
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/18/2020 3:39:27 PM
Creation date
5/18/2020 3:16:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0545782
PE
2965
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
02
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Revised Monitoring and Rt-,,rting Program No. 93-100 7 <br /> Lawrence Livermore National Laboratory Site 300— Pit 1 <br /> San Joaquin County <br /> Table 3 (continued): Pit 1 Constituents of Concern, Detection Monitoring <br /> Wells, Statistical Methods, Concentration Limits, and Statistical Limits <br /> Constituent Detection Statistical Method Concentration Statistical <br /> of Concern Monitoring Limit' Limit <br /> Wells <br /> Uranium K1-02B Intrawell Prediction Limit 1.83 2.43 <br /> (total) K1-04 Intrawell Prediction Limit 0.97 1.51 <br /> K1-05 Intrawell Prediction Limit 1.55 2.13 <br /> K 1-08 Intrawell Prediction Limit 1.96 2.61 <br /> K1-09 Intrawell Prediction Limit 1.93 2.40 <br /> W-PIT1-2326 Intrawell Prediction Limit 1.67 2.06 <br /> Thorium-228 K1-02B Intrawell Prediction Limit 0.016 0.076 <br /> K1-04 Intrawell Prediction Limit 0.011 0.133 <br /> K1-05 Intrawell Prediction Limit 0.015 0.086 <br /> K 1-08 Intrawell Prediction Limit 0.025 0.098 <br /> K1-09 Intrawell Prediction Limit 0.011 0.222 <br /> W-PIT1-2326 Intrawell Prediction Limit 0.009 0.090 <br /> Thorium-232 K1-02B Intrawell Prediction Limit 0.012 0.121 <br /> K1-04 Intrawell Prediction Limit 0.006 0.037 <br /> K1-05 Intrawell Prediction Limit 0.014 0.109 <br /> K 1-08 Intrawell Prediction Limit 0.014 0.116 <br /> K1-09 Intrawell Prediction Limit 0.005 0.049 <br /> W-Pitt-2326 Intrawell Prediction Limit -0.0022 0.039 <br /> Salts/Anions <br /> Perchlorate K1-02B Intrawell Prediction Limit 7 10 <br /> (Ng/L) K1-04 Reporting Limit Reporting Limit 4 <br /> K1-05 Reporting Limit Reporting Limit 4 <br /> K1-08 Reporting Limit Reporting Limit 4 <br /> K1-09 Reporting Limit Reporting Limit 4 <br /> W-PIT1-2326 Intrawell Prediction Limit 6 9 <br /> 'Concentration limits represent the average of the historical concentrations in each well. <br /> 2See required action 15 <br /> 3 Reporting Limit. The concentration limit is representative of background and is calculated using an <br /> average. Where all sampling results are below the analytical method reporting limit, an average value <br /> cannot be calculated and establishing a concentration limit for the development of the statistical limit <br /> is not applicable. The reporting limit becomes the concentration limit and the statistical limit. <br /> 4Radioactivity measurements are corrected for the background radioactivity inside the measurement <br /> chamber. A negative value for radioactivity indicates that the average of the sample(s) measured <br /> lower than the instrument background by the amount shown and the actual value is very close to <br /> zero. <br /> 5The concentration limit may be set for an individual constituent at a level higher than natural <br /> background for the well if monitoring has determined that groundwater is impacted by the individual <br /> constituent. This allows the Discharger to evaluate whether concentrations are trending upward or a <br /> new release has occurred. Site wide background for tritium is approximately 100 pCi/L. Groundwater <br /> both up and downgradient of Pit 1 has been impacted with tritium above background concentrations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.